Laserfiche WebLink
EnCon Services, Inc. <br /> Sign Design Calculations <br /> Job Description PREPARED BY: EnCon Services, Inc. <br /> Ross#1612 2272 Jaudon Road <br /> US Hwy 301 & Pretty Pond Rd. Dover, FL 33527 <br /> Zephyrhills, Florida 813-655-3373 <br /> 23"x 46" Under Canopy Sign F 813-655-9814 <br /> Design per 2010 Florida Building Code, Section 16 Wind Load <br /> ASCE 7-10, Load Case: D+0.6W Aaron Biedenbach, P.E. <br /> FL PE#52949, FL EB 9394 <br /> Risk Category II OH PE 60756, OC#01893 <br /> Kzt 1 KY PE #20281, P#2463 <br /> Exposure B IN PE#PE 19600322 <br /> Kd 0.85 FL CBC#060535, QB#22527 <br /> Kz 0.7 <br /> V 150 mph <br /> GCp-GCpi 1.28 Zone 4, H<60 Feet <br /> Wind Pressure <br /> Number of Poles 2 44 PSF <br /> Sign Area Distance to Center P=Force Moment <br /> sf ft (ib) ft-Ib <br /> Sign Cabinet 7.30 4.96 192 953 <br /> 0 0 <br /> 0 0 <br /> 0 0 <br /> Totals 192 953 <br /> Required Sx 0.25 inches cubed per pole <br /> Provided Sx 0.326 1-1/2" (0.145 wall)A53 B Steel Pipe OK <br /> 1 1/2" PIPE THRU 4"TUBE CROSS MEMBER BOLTED TO CEILING FRAMING MEMBERS. <br /> �����g1EDFjye'''.� <br /> `���Q• �.... �4 � <br /> � � �+G�N S � .� �f► � <br /> ��` Q '� � � <br /> � � ' 9 � W� <br /> '�► �C ; � • W . <br /> � E�,�, : Z � <br /> =� � 5 � `O•� �``� <br /> � � U � 0� • � \ <br /> � '�.••�' �. �� <br /> '�•;cSSI ON P►�' ,��� <br /> °�ds,leldd�� <br /> Ross 1612 Zephyrhills 23x46 under canopy sign <br /> 6/3/2013 <br />