My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
13-14731
Zephyrhills
>
Building Department
>
Permits
>
2013
>
13-14731
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/28/2014 8:53:02 AM
Creation date
7/28/2014 8:52:57 AM
Metadata
Fields
Template:
Building Department
Company Name
HOBBY LOBBY
Building Department - Doc Type
Permit
Permit #
13-14731
Building Department - Name
MERCHANTS STATION LLC
Address
7325 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
89
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SpectrAlert Advance Specifications <br /> .- . <br /> General <br /> SpectrAlert Advance strobes and horn strobes shall mount to a standard 4 x 4 x 1'/z-inch back box,4-inch octagon back box,or double- <br /> gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17B-inch back box.A universal mounting plate shall be used for <br /> mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,SpectrAlert <br /> Advance products,when used with the Sync•Circuit'"Module accessory,shali be powered from a non-coded notification appliance circuit <br /> output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module,12-voit-rated notification appliance circuit <br /> outputs shall operate between 9 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall opera[e between 17 and 33 volts. <br /> Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectitied <br /> unfiitered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15. 15175,30,75,95. 110, 115,135, <br /> 150, 177,and 185. <br /> Strobe <br /> The strobe shail be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective serwce. <br /> The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for <br /> visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash <br /> tube and associated lens/retlector system. <br /> Horn Strobe Combination <br /> The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for <br /> fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with <br /> Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light <br /> shall consist of a xenon flash tube and associated lenslreflector system.The horn shall have three audibility options and an option to switch <br /> between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.On four-wire <br /> products,the strobe shall be powered independently of the sounder.The horn on horn strobe models shall operate on a coded or non-coded <br /> power supply. <br /> Synchronization Module <br /> The module shall be a System Sensor Sync•Circuit model MDL listed to UL 464 and shail be approved for fire protective service.The module <br /> shali synchron¢e SpectrAlert strobes at 1 Hz and homs at temporal three.Also,while operating the strobes the module shali siience the horns <br /> on hom strobe models over a single pair of wires.The module shall mount to a 411/16 x 411/16 x 21B-inch back box.The module shall also <br /> control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more <br /> synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power suppiy. <br /> Standard Operating Tempewature 32°F to 120°F(0°C to 49°C) <br /> Humidity Range 10 to 93%non-condensing <br /> Strobe Fiash Rate 1 flash per second <br /> Nomina!Voltage Regulated 12 DC/FWR or regulated 24 DClFWR' <br /> Operating Voitage Range2 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) <br /> InputTerminal Wire Gauge 12 to 18 AWG <br /> Ceiling-Mount Dimensions(including lens) 6.8 diameter x 2.5"h�gh(173 mm diameter x 64 mm high) <br /> Ceiling-Mount Back Box Skirt Dimensions(BBSC-2,BBSCW-2) 7 1 diameter x 2.2""high(180 mm diameter x 57 mm high) <br /> Ceiling-MountTrim Ring Dimensions(soid as a 5 pack)(TRC-HS, 6.9""diameter x 0.35"high(175 mm diameter x 9 mm high) <br /> TRCW-HS) <br /> Notes: <br /> t Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. <br /> 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. <br /> nvcsooso, <br />
The URL can be used to link to this page
Your browser does not support the video tag.