My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
13-14731
Zephyrhills
>
Building Department
>
Permits
>
2013
>
13-14731
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/28/2014 8:53:02 AM
Creation date
7/28/2014 8:52:57 AM
Metadata
Fields
Template:
Building Department
Company Name
HOBBY LOBBY
Building Department - Doc Type
Permit
Permit #
13-14731
Building Department - Name
MERCHANTS STATION LLC
Address
7325 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
89
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' � � • <br /> . . . .,, y . . w < . Frn. ...,.. . �. <br /> �� .. <br /> '='� . ����� <br /> it�venfied fQr lif� <br /> D125B Dual Class B Initiating Module <br /> ► Two separate powered detector loops <br /> ► Suitable for 12 VDC or 24 VDC,two-wire smoke <br /> ""' '"" vosa detectors <br /> o�zes ��° �y�; ► Suitable for four-wire smoke detectors <br /> �� II ► U to 50 two-wire 12 VDC lass break detectors <br /> �� p g <br /> ► Reports individual loop alarm,individual loop trouble, <br /> and ground fault <br /> ► Manually resets latching devices from control panel <br /> ► Remote central station reset <br /> The D125B has two separate NFPA Class B (Style B) To supervise the loops, install an end-of-line (EOL) <br /> powered loops The module supervises each of the loops resistor beyond the last detector of each protective loop <br /> for opens, shorts, or ground faults. Both loops can be If you are replacing a D125 or D125A Module with the <br /> powered with either 12 VDC or 24 VDC to connect D125B,use the 1.5 kf] resistor(P/N: 15-03130-000) <br /> compatible two-wire detectors or other two-or four-wire installed with the original system If you are installing a <br /> devices such as retarded waterflow switches, manual D1256 in a new system or are adding additional devices <br /> stations, heat detectors, or glass break detectors. to an existing system, use the 1.8 kfl resistor(P/ <br /> The D125B is suitable for connecting fire or burglary N: FO1U009011) supplied with the module. <br /> devices in commercial, industrial, and institutional The D125B shorts the protective loop on the control panel <br /> applications. Schools, offices,and health care facilities when the high (+) and low (-) side of either module(oop is <br /> are typical commercial applications shorted together or when a smoke detector activates.The <br /> D125B opens the protective loop on the control panel <br /> during the following conditions: <br /> Functions • Either of the module protective loops are opened. <br /> Loop Supervision • The D125B Interface module is unpowered <br /> • Either the high (+) side of the loop or the low (-) side <br /> The D125B needs to be electrically connected to earth of the loop is shorted to ground <br /> ground and to the contro) panel's common The D1256 With the D9412GV3, D7412GV3, D7212GV3, D9412GV2, <br /> has a supervisory output terminal for each of its loops. All D7412GV2, D7212GV2, D9412G, D7412G, and D7212G <br /> terminal designations are clearly marked on the module Control Panels,a short to ground causes a ground fault <br /> circuit board condition when ground fault detect is enabled <br /> When programming for fire applications, refer to the <br /> appropriate control panel's operation and installation <br /> guide. <br /> Warning Do not mix 12 VDC and 24 VDC detectors on <br /> the same D1256 Module. <br /> www.boschsecurity.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.