My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
13-14798
Zephyrhills
>
Building Department
>
Permits
>
2013
>
13-14798
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/28/2014 10:21:33 AM
Creation date
7/28/2014 10:21:32 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
13-14798
Building Department - Name
NUGENT,PATRICIA
Address
5519 16TH ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
R R W Building Consultants, Inc. <br /> W Consulting and Engineering 5ervices for the Building Industry <br /> Bp.O Hnx230Valr:co,FLJ3S95 Pho..eg�3,639.9197 <br /> CFlorida Board of Professional En�ineers Certificate of Authorization No.9813 <br /> Product <br /> Category Sub Category Manufacturer Product Name <br /> Alsfde Window Company Mode10201 <br /> Window Double Hung 3773 State Road Extruded Vinyl <br /> Cuyahoga Falls,OH 44223 Double Hung�Window <br /> Phone 330.922.2108 "Non-Im act" <br /> Scope: Product Evaluation report issued by R W Buliding Consultants,Inc.&Lyndon F.Schmidt,P.E.(System ID#1998)for <br /> Alside Window Company,based on Rule Chapter No.9N-3,Method 1 D of the State of Florida Product Approval,Dept.of <br /> Business&Professional Regulation. <br /> RW Building Consultants and Lyndon F.Schmidt,P.E.do not have nor wiil acquire financial interest in the company manufacturing <br /> or distributing the product or in any other entity involved in the approval process of the product named herein. <br /> Limitations: <br /> 1 This product has been evaluated and is in compliance with the 2007/2010 Florida Building Code structural requirements excluding the <br /> "High Velocity Hurricane Zone" <br /> 2. Product anchors shall be as fisted and spaced as shown on details.Anchor embedment to base material shall;be beyond wall dressing <br /> or stucco. <br /> 3. When used in areas requiring wind bome debris protection,this product is required to be protected with an impact resistant covering that <br /> complies with Section 1609 1.2 of the Florida Building Code. <br /> 4 Site conditions that deviate from the details of drawing FL-8134.1 require further engineering analysis by a licensed engineer or <br /> registered architect. <br /> 5. For 2X stud construction,anchoring of the assemblies shall be as shown for 2X buck masonry construction. <br /> 6. See drawing FL-8134 1 for size and design pressure limitations. <br /> Supporting Documents: <br /> 1 Test Reqort No. Test Standard Testinq Laboratorv Sipned bv <br /> ATI 97028 02-501-47 AAMA/WDMA/CSA 101/I.S.2/A440-08 Architecturel Testing,Inc. Lynn George <br /> 2. Drawinn No. Pre�ared bv Sianed�Sealed bv <br /> No.FL-8134 1 RW Building Consultants,Inc.(CA#9813) Lyndon F.Schmidt,P.E. <br /> 3. Calculations Pre�ared bv Siqned 8�Sealed bv <br /> Product Anchoring RW Building Consultants,Inc.(CA#9813) Lyndon F.Schmidt,P.E. <br /> Buck Anchoring RW Building Consultants,Inc.(CA#9813) Lyndon F.Schmidt,P.E. <br /> 4 Qualitv Assurance <br /> Certificate of Participation issued by Architectural Testing, Inc., certifying that Alside Window Company is <br /> manufacturing products within a quality assurance program that complies with ISO/IEC 17020 and Guide 53. <br /> � <br /> �� � <br /> Lyndon F.Schmidt,P.E. <br /> FL PE No.43409 <br /> PF 1273 Sheet 1 of 1 3/5/2013 <br />
The URL can be used to link to this page
Your browser does not support the video tag.