P P TTER `'�R <br /> O VANE TYPE WATERFLOW <br /> � The Symbol of Protection ALARM SWITCH WITH RETARD <br /> iJL,CiJL and CSFM Listed,FM Approved,LPCBApproved,For <br /> CE Marked(EN12259-5)/VdS Approved model use V SR-EU <br /> �I� Service Pressure: 450 PSl(31 BAR)-UL <br /> Flow Sensitivity Range for Signai: <br /> 4-10 GPM(15-381LPM)-UL <br /> Maximum Surge: 18 FPS(5.5 m/s) <br /> Contact Ratings: TwosetsofSPDT(FormC) <br /> 10.0 Amps at 125/250VAC <br /> 2.OAmpsat30VDC Resistive <br /> 10 mAmps min.at 24VDC <br /> Conduit Entrances: Two knockouts pravided for 1/2"conduit. <br /> Individual switch r,ompartments suitable <br /> for dissimilar voltages. <br /> Environmental Specifications: <br /> • NEMA 4/[P54 Rated Enclosum suitable for indoor or <br /> outdoor use with factory installed gasket and die-cast housing <br /> when used with appropriate conduit fitting. <br /> • Temperature Range: 40°F-120°F,(4.5°C-49°C)-UL <br /> • Non-conosive sleeve factory inistalled in saddle. <br /> Service Use: <br /> Automatic Sprinkler NFPA-13 <br /> Specifications subject to change without notice. One or two family dwelling NFPA-13D <br /> Ordering Information Residential occupancy up to four stories NFPA-13R <br /> Nominal Pipe Size Model Part Number National Fire Alann Code NFPA-72 <br /> 2" DN50 VSR-2 1144402 <br /> 21/2" DN65 VSR-21/2 1144425 <br /> 3" DN80 VSR-3 1144403 • Installation must be performed by quailified personnel and in <br /> 3 1/2" - VSR-3 1/2 1144435 accordance with all national and local codes and ordinances. <br /> • Shock hazard.Disconnect power source before servicing.Serious <br /> 4" DNI00 VSR-4 1144404 injury or death could result. <br /> 5" - VSR-5 1144405 • Risk of explosion.Not for use in haz:udous locations.Serious <br /> 6" DN150 VSR-6 ll44406 injury or death could result. <br /> 8" DN200 V3R-8 1144408 <br /> Optional: Cover Tamper Switch Kit,stock no.0090148 �"`��v"' <br /> ReplaceableComponents:Retard/SwitchAssembly,stockno. 1029030 Waterfiowswitchesthataremonitoringwetpipesprinklersystemsshall <br /> not be used as the sole initiating device:to discharge AFFF, deluge, <br /> or chemical suppression systems. Waterflow switches used for this <br /> application may result in unintended discharges caused by surges, <br /> trapped air,or short retard times. <br /> General Information Enclosure <br /> The Model VSR is a vane type waterfiow switch for use on wet sprinkler The VSR switches and retard device aze c;nclosed in a general purpose, <br /> systems. It is UL Listed and FM Approved for use on steel pipe; die-cast housing. The cover is held in place with two tamper resistant <br /> schedules 10 through 40,sizes 2"thru 8" (50 mm thru 200 mm). LPC screws which require a special key for removal. A field installable <br /> approved sizes are 2" thru 8" (50 mm thru 200 mm). See Ordering cover tamper switch is available as an option which may be used <br /> Information chart. to indicate unauthorized removal of the covec See bulletin number <br /> The VSR may also be used as a sectional waterfiow detector on lazge 5401103 for installation instructions of this switch. <br /> systems.The VSR contains two single pole,double throw,snap action <br /> switches and an adjustable,instantly recycling pneumatic retard. The <br /> switches are actuated when a flow of 10 GPM(38 LPM)or more occurs <br /> downstream of the device. The flow condition must exist for a period <br /> of time necessary to overcome the selected retard period. <br /> Potter Electric Signal Company, LLC • St. Louis, MO • Phone• 866-956-12ll/Canada 888-882-1833 • www pottersignal.com <br /> PRINTED 1N USA MFG.#5401146-REV L PAGE 1 OF 4 <br /> 3/09 <br />