Laserfiche WebLink
FORM 405-10 <br /> Florida Code Compiiance Checklist - <br /> Florida Deparfinenf of Business and Professiona!Regulations <br /> Residenfia/ Whole Buiiding Performance Mefhod <br /> ADDRESS: 4408 Court Street PERM/T#: <br /> Zephyrhills,FL, 33542- <br /> MANDATORY REQUIREMENTS SUMMAI�Y-See indtvidual code sections for full details. <br /> COMP�NENT SECTION SUMMARYOF REQUIREMENT(S) CHECK <br /> Airleakage 402.9 To be cau/ked,gaskefed, weatherstripped orofhen�vise sea/ed. <br /> Recessedlighting IC-rated as meeting ASTM E 283. Windows and <br /> doors=0.30 cfm/sq.ft. Testing or visual inspection required. ✓ <br /> Fir�eplaces:gasketed doors&outdoor combustion air. Must complete <br /> envelope leakage report or visually verify Table 402.4.2. <br /> rneR►►osrar a -t03.1 Atleast one thermostat shall be provided foreach separate heating <br /> conProls and coo/ing system. Whens for+ced-air fumace is primary system, <br /> programmable thermosfat is required.HQat.pumps with supplementai � <br /> e/ectric heaf must prevent supp/ementa!fieat when compressor can <br /> meet the load. <br /> oucts 403.2.2 A!!ducts, air handlers, filter boxes and building cavifies which form the � <br /> primary aircontainment passageways forair�Iisfribution systems shall <br /> be consider+�d ducts or plenum chambers,shall be constructed and � <br /> sealed in accordance wifh Section 503.2.7.2 of this code. <br /> 403.3.3 Building framing cavities sha11 not be used as suppJy ducts. <br /> Water heaters d03.4 Heaf trap required for verflcal pipe risers. Comp/y with efficiencies in <br /> Table 403.4.3.2. Provide switch or Gearly marked circuit breaker �-. <br /> (e/ectric)or shutoff(gas). CirGUlating system pipes insulated to= <br /> R-2+accessrble manua!OFF switch. � , <br /> Mechan�cal ao3.5 Homes designed to operate at positive pressure or with mechanica! <br /> ventilation ventilation systems shall not exceed the minimum ASHRAE 62/evel. � <br /> . No make-up air from attics,craw/spaces,garages oroutdoors adjacent ✓ <br /> , to pools or spas. �J�,.�� - <br /> SwimmingPools 403.9 •poo/pumps and pool pump motors wlth a tota!hoisepow�r(HPJ of= '1 <br /> &S�as � . ., HP�shall have the capabilify of operatfng at two or more speeds. Spas <br /> ,. ' � and heated poo/s must have vapor-retarolant covers or a liqpid cover or, <br /> , - • � _ oti►ermeans proven to reduce heatloss except if709�C of heat from <br /> � � <br /> site-recovered energy, OffRimer switch required. Gas heaters minimum �{�� <br /> thermal e�ciency=78%(82%after 4/16/13). Heat pump pool heaters / " <br /> minlmum COP=4.0. <br /> Cooiingfiee�ng 403.6 Slzing ca/cu/ation pertormed&atfached. Minimum efficiencJes per <br /> •Tab/es 503.2.3.Equipment efficiency ve�cation required. Specia! <br /> equlpment o0�as/on cooling or heating capaciry requfres separate system or ,� <br /> variab/e capacity system. Elecfric heat>lOkW must be divided into two <br /> or more stagss. • <br /> Ceilingsllcneewalls 405.2.1 R-19 space permitting. <br /> 1 l/4/2013!1:90 AM EneryyGauqe�U5A-F1aRes2010 Sectiort 405.4.1 Compliant Soltware Pape 5 of 5 <br /> � _ . ,.. . _ __.,.___—... ._ . .. . - <br />