Laserfiche WebLink
Rhvac-Residential 8 Light Commercial HVAC Loads Elite Software Development,lnc. <br /> HVAC Designs � WaMut Grove TH 1129 N <br /> Tam a,FL 33615 Pa e 4 <br /> Manual D Ductsize Data-Duct S stem 1 •Return <br /> —Duct Name,etc. <br /> Type Roughness Diameter Velaity SPL.Duct <br /> Upstream Temperature Width Loss1100 SPL.Fit <br /> Shape Length Height FitEq.Len SPL.Tot <br /> Sizin CFM Area SP.Avail SPL.Cumul <br /> --�uct Name:RMT•100,Feeds From:Foyer,Fitting:5-B,Effective Length:38.0 <br /> Trunk 0.003 12.4 665 0.002 <br /> Up:Fan 75 10 0.082 0.029 <br /> Rect 3.0 13 35.0 0.031 <br /> Schedule 600 11.5 -0.018 0.050 <br /> —Duct Name:RR-100,Returns From:Foyer,Fitting:2-D,Effective Length:22.2 <br /> Runout 0.003 12.4 665 0.001 <br /> Up:RMT•100 75 10 0.082 0.017 <br /> Rect 1.0 13 21.2 0.018 <br /> Schedule 600 3.8 0.000 0.018 <br /> _ . __._.. __ _ _._ ..... _.. _.__. .___._._ _._..._ _ .._ _.__ ........ <br /> Report Units:Pressure:in.wg,Duct lengths:feet,Duct sizes:inch,Airflow:CFM,Velocity:ft.lmin,Temperature:F <br /> Notes: Static pressure available values for return ducts are at the entrance of the duct For supply,they are at the exit The cumulative static <br /> pressure loss value for a return trunk is with respect to the entry point of the return runout upstream with the highest static pressure available. Total <br /> and cumulative static pressure loss values for the supply main trunk include any device pressure losses entered,and the cumulative may also <br /> include the total static pressure loss of the return side. <br /> Summa <br /> Number of active trunks: 1 <br /> Number of active runouts: 1 <br /> Total runout ouUet airflow: 600 <br /> Main trunk airflow: 600 <br /> Largest trunk diameter: 12.4 RMT•100 <br /> Largest runout diameter: 12.4 RR-100 <br /> Small•stVunkdiameter: 12.4 RMT-100 <br /> Small•strunoutdiameter: 12.4 RR-100 <br /> Runout maximum cumulative static pcessure loss: 0.018 RR•100 <br /> Return loss added to supply: 0.050 <br /> Total effective length of return(R): 60.2 RR•100 <br /> System duct surface area(Scenario 4): 15.3 Exposed in Space (Linked to duct load) <br /> Total system duct ourface area: 15.3 <br /> Notes <br /> Rhvac is an ACCA approved Manual J and Manual D computer program. <br /> Calculations are performed per ACCA Manual J 8th Edition,Version 2,and ACCA Manual D. <br /> All omputed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. <br /> Monday,November 04,2013,12:09 PM <br />