My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
13-14840
Zephyrhills
>
Building Department
>
Permits
>
2013
>
13-14840
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/11/2014 1:01:03 PM
Creation date
11/11/2014 1:00:45 PM
Metadata
Fields
Template:
Building Department
Company Name
WALNUT GROVE TOWNHOMES
Building Department - Doc Type
Permit
Permit #
13-14840
Building Department - Name
BUTTERFIELD MOBILE HOME
Address
37845 PRAIRIE ROSE LP LOT 26
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FORM 405-10 <br /> Florida Code Compliance Checklist - <br /> F/orida Department of Business and Professional Regulations <br /> Resrdenfial Whole Building Performance Method <br /> ADDRESS: 4408 Court Street PERM/T#: <br /> Zephyrhills,FL,33542- <br /> MANDATORY REQUIREMENTS SUMMARY-See Individual code sections for full details. <br /> COMPONENT SECTION SUMMARYOF REQUIREMENT(S) CHECK <br /> Airleakage 402.4 To be caulked,gasketed, weafherstripped orotherwise sea/ed. <br /> Recessed lighting 1Grated as meeting ASTM E 283. Windows and <br /> doors=0.30 cfm/sq.ft. Testing or visua!inspection r�equired. ✓ <br /> Fir+ep/aces:gasketed doors&outdoor combustion air. Must complefe <br /> envelope/eskage report or visually verify Table 402.4.2. <br /> Thermostat 8 403.1 Atleast one them►osfaf shal!be provided for each separate heating <br /> controts and cooling system. Where forced-afr fumace is primary system, • / <br /> prag�ammab/e thermostat is required.Heat pumps with supplemental � <br /> e/ectric heat must pnevent supplementa/heaf when compressor can <br /> meet the load. <br /> Ducts 403.2.2 All ducts, airhandlers, filterboxes and 6uilding cavities which form the � <br /> primary arr containmenf passageways for air distribufion systems shall <br /> be considered ducts or plenum chambers,shel!be constructed and � <br /> sea/ed in accorrlance with Section 503.2.7.2 of fhis code. <br /> 403.3.3 8uilding framing cavities shal!not be used as supp/y ducts. <br /> Water heaters 403.4 Heat trap requirtsd for vertica!pipe risers. Comply with e�ciencies in <br /> Table 403.4.3.2.Provide swifch or clea�ly maiked eincuit breaker .1/ <br /> (electria)or shutoff(gas). Ci�u/ating system pipes insufated to= <br /> R-2+accessib/e manua!OFF switch. <br /> Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical <br /> venUlation ventilation systems shal!not exceed the minlmum ASHRAE 62/evel. " <br /> . No make-up air from attics,crawlspaces,garages or outdoors adjacenf ✓ <br /> . to pools or spas. J��� - <br /> SwimmingPools 403.9 'Poo/pumps and poo/pump motors with a tota!horsepower(HP)nf= 1 <br /> &Spas ,. HP`shalf have the capabilrfy of oper�ting at fwo or more speeds. Spas <br /> � , " and heated poo/s musf have vapor-retandant covers or a Ifqpid cover or� <br /> , � • , — other means proven to reduce heat loss except if 709�o af heat from <br /> � , site-necovered energy. Ofl'�timer switch r�qu/red. Gas heafers minimum `��- <br /> therma!e�ciency=78�(82%after 4/16/13). Heat pump pool heaters , � " <br /> minimum COP=4.0. <br /> Cooling/headrlg 403.6 Sizing calculation performed&attached. Minimum efficiencies per <br /> �Tab/es 503.2.3.Equipment e�ciency verif/cation reyuired. Specia/ � <br /> equipment odl�asion cooling or heating capacity requires separate system or <br /> variable capacity system. E/ectric heat>10kW must be divided into two <br /> or mone stages. � <br /> CeJlings/kneewa!!s 405.2.1 R-19 space permitting. <br /> 11/4r101312:22 PM EnerpyGauqe�USA-FlaRes20f 0 Secfion 405.4.1 Complisnt SoA'waro Paqe 5 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.