My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
13-14841
Zephyrhills
>
Building Department
>
Permits
>
2013
>
13-14841
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/11/2014 1:02:07 PM
Creation date
11/11/2014 1:01:50 PM
Metadata
Fields
Template:
Building Department
Company Name
WALNUT GROVE TOWNHOMES
Building Department - Doc Type
Permit
Permit #
13-14841
Building Department - Name
BUTTERFIELD MOBILE HOME
Address
37843 PRAIRIE ROSE LP LOT 27
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FORM 405-10 <br /> Florida Code Compliance Checklist - <br /> Florida Department of Business and Professiona!Regulations <br /> Residenfial Whole Building Performance Method <br /> ADDRESS: 4408 Court Street PERMIT#: <br /> Zephyrhills,FL,33542- <br /> MANDATORY REQUIREMENTS SUMMAI�Y-See individual code sections fo�full detaiis. <br /> CpMPONENT SECTION SUMMARY dF REQUlREMENT(S) CHECK <br /> Airleakage 402.4 To be caulked,gasketed, weathersfripped or otherwrse sealed. <br /> Recessed lighting/C-rated as meefing ASTM E 283. �ndows and � <br /> doors=0.30 cfm/sq.ft. Testing or visua!inspection requirt�d. <br /> Finep/aces:gasketed doors&outdoor combustion air. Must complete <br /> enve/ope/eakage report or visuaqy verify Tab/e 402.4.2. <br /> Thermostat& 403.1 At least one fhermostat shal!be provided for each separate heating <br /> controls and cooling system. Where fo�ed-air fumace is primary system, <br /> programmab/e therrnostat is r+equireal.Heaf.pumps with suppJeri�enta/ d <br /> e/ectric heat must pr+avent supp/ementa/heat when compressorcan <br /> meet the load. <br /> Ducfs 403.2.2 All ducts,air handJers, frlter boxes and building cavities which form the � <br /> primary air containmenf passageways for air qlistribution systems sha11 <br /> be considered ducts or p/enum chambers,shall be constructed and <br /> sealed in accordance with Section 503.2.7.2 of this code. � <br /> 403.3.3 Building framing cavities shal!nof be used as supp/y ducts. <br /> Wster heaters 403.4 Heat trap required for vertical pipe rrse►s. Comp/y w/th elficiencies in <br /> Table 403.4.3.2. Provide switch or c/esriy marked ci�uit bresker �/ <br /> (electric)orshutoff(gas). Circulating system p/pes insu/ated fo= <br /> R-2+accessible manua/OFF switch. � , <br /> Mechanical 403.5 Homes designed to operate at positive pressure or with mechanica! <br /> ventllaSon ventrlat�on systems shal!not exceed the minimum ASHRAE 62/eveL � <br /> . No make-up a1r from attics, craw/spaces, gareges or outdoors adjacent ,� <br /> , to pools or spas. _ <br /> -�. .-)F� <br /> SwimmingPools 403.9 'Poo/pumps and pool pump motors with a tota/horsepower(HP)of= 1 <br /> &Spas ; . .. HP'shail have the capability of operating at two or morts speeds. Spas <br /> � • � and heated poo/s must have vapor-►etardant covers or a liquid cover or� � <br /> � � � • — other means pr�ven to rtsduce heat foss ext�ept if 7096 of heat from <br /> � .. , site-recovered energy. Offit►mer swifch required. Gas heaters minimam - <br /> them►a/e�ciency=78%(82%aRer 4/16/13). Heat pump poo/hesters , �A - <br /> minimum COP=4.0. <br /> Coolinsyt►eaBng 403.6 Sizing calcu/ation performed&attached.Minimum efficiencies per <br /> �Tables 503.2.3.Equipmenf e�ciency verlflcation nequ/red. Specral �/ <br /> equipment odrasion cooling or heating capacity nequires separate system or <br /> varisble capacfty system. Electric heat>10kW must be divided into two <br /> or more stages. • <br /> CeilingsAcnsewalls 405.2.1 R-�9 space permitting. <br /> f 1/4/2013 J0:50 AM EnerpyGaupe�USA-FfaRes2010 Sectlon 405.4.1 Complienf SofAvare PaQe 8 of 8 <br /> _ �.- _ ._„-_ _._...� .. . .'. . . .._.. ` <br />
The URL can be used to link to this page
Your browser does not support the video tag.