Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
<br /> NVAC Designs Wa/nut Grove TH 1505 N
<br /> Tam a,FL 33615 Pa e 7
<br /> System 1 Room Load Summary
<br /> Htg Min Run Run Clg Clg Min Act
<br /> Room Area Sens Htg Duct Duct Sens Lat Clg Sys
<br /> No Name SF Btuh CFM Size Vel Btuh Btuh CFM CFM
<br /> — one 1—
<br /> Foyer 71 2,049 47 4 • 917 80 46 49
<br /> 3 Bed 2 180 4,154 94 6 • 2,384 440 121 127
<br /> 4 Bath 2 60 746 17 4 • 376 60 19 20
<br /> 5 Kitchen 283 325 7 6 - 2,258 500 114 121
<br /> 6 Bed 3 171 2,131 48 5 • 1,569 221 79 84
<br /> 7 Great 1 Dining 335 5,602 127 7,7 • 5,885 1,485 297 314
<br /> 8 M Bed 248 4,708 107 6 - 2,121 517 107 113
<br /> 9 M Wic 39 45 1 4 • 80 0 4 4
<br /> __10 M Bath
<br /> ---- ---- ----118-- - __136 _- 3 4 '
<br /> 338 80 17 1g
<br /> -- -- —--_ ---_ ------
<br /> _ ----302._ --
<br /> --— ---- -__
<br /> ___ __ uct Latent
<br /> _
<br /> _ _ _
<br /> __ _ ____...
<br /> _
<br /> S.ygtem 1 total 1,505 19,896_ _ 452 _ 15,928_ 3 685 805 850
<br /> System 1 Main Trunk Size: 1�c14 in.
<br /> _�_ _. _._.
<br /> Velocity: 729 ft.lmin
<br /> Loss per 100 ft.: 0.086 in.wg
<br /> Duct size results above are from Manual D Ductsize.
<br /> Runout duct velaities are not printed with duct size results from Manual D Ductsize since they can vary within the room. See the Manual D Ductsize
<br /> report for duct velocities and other data.
<br /> Cooling System Summary
<br /> Cooling SensiblelLatent Sensible Latent Total
<br /> Tons Split Btuh Btuh Btuh
<br /> Recommended �,�� 75%125°k 15,928
<br /> 5,309 2�,y37
<br /> Actual: 2.08 75%!25°/. 18,750 6,250 25,000
<br /> Equtpment Data ,
<br /> Heatina Svstem Coolina Svstem
<br /> TYPe� A1r Source Heat Pump Air Source Heat Pump
<br /> M�e�� 4A6H3024C1 4A6H3024C1
<br /> Indoor Model: GAF2AOA24S21+TDR
<br /> Brand: HEWTAGE 13 HERITAGE 13
<br /> Descrlption: Air Source Heat Pump Air Source Heat Pump
<br /> Efflclency: 8.2 HSPF 13.75 SEER
<br /> Comment: �
<br /> Sound: 0 0
<br /> Capacity: 23,600 Btuh 25,000 Btuh
<br /> Sencible Capaclty: nla 18,750 Btuh
<br /> Latent Capacity: nla 6,250 Btuh
<br /> AHRI Reference No.: nla 4941302
<br /> Thls system's equipment was selected in accordance wlth ACCA Manual S.
<br /> Manual S equlpment�izing data: SODB:93F,SOWB:77F,WODB:40F,SIDB:75F,SIRH:55%,WIDB:72F,Sen.gain:15,928 Btuh,Lat gain:3,685
<br /> Btuh,Sen.losc:19,896 Btuh,Entering clg.coll DB:75F,Entering clg.coil WB:63.9F,Entering htg.coil DB:72F,Cig.coil TD:18F,Htg,coil TD:40F,
<br /> Req.clg.airflow:805 CFM,Req.htg.alrflow:452 CFM
<br /> Monday,November 04,2013,11:20 AM
<br />
|