Laserfiche WebLink
Minimum 1"thick N/A NJA <br /> Fiber Base,RetraFit <br /> Minimum '/:"thick N/A NlA <br /> Note: AU layers shxli be simultaneously fastened; see top laycr below for fasteners and density. Insulation <br /> panels listed are minimum sizes and ctimensions;if larger panels are used,the number of fasteners shall be <br /> increased maintaining the same fastener density, . Please refer to Roofing Application Standard RAS 117 for <br /> insulation attachment. <br /> Tun Insulation Lave�• Insulation Fasteners Fastener <br /> Tabie 3 Densitv/ft= <br /> Required uver the insulations listed in Base Layer. <br /> Dens Deck Prime(For use over all insulation types.) <br /> Minimum"/."thick 1, 11), 11, 12,2G or 28 1:1.33 tt$ <br /> Nntc: InsWation paneEs listed are minimum sizes and climensions;if larger panels are used,the number af <br /> fastenerY shall be increased rnaintaining the same fastener denslty. Please refer to Rooting AppGcation Standard <br /> RAS I I7 f�►r insutation attachment. <br /> L'apor Retarder: (Qpuanal) Any UL or FMRC approved vapor retarder applied to the roof deck or over a base <br /> layer of insulauon. <br /> Barrier: None. <br /> Membrnne: TPC?-c or TPO-c FR, Reinforced, 45 or GO mil membrane or TPO-c EXTRA. 72 or 80 mil <br /> membrane fulty adhered to the insulation using TPO Bonding Adhesive applied to thc substratc <br /> at a rate of! gaV60 f�.=. <br /> Maa�imam Design <br /> Pressure: —90 psf(See General Limitation#7) <br /> �IOr1 No.: 13-U411.(W <br /> �••. �� Expiration Date: 08/31l14 <br /> Appro��ai Date: 08i29/13 <br /> Pa�e 14 of 18 <br />