My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
13-14858
Zephyrhills
>
Building Department
>
Permits
>
2013
>
13-14858
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/11/2014 1:15:09 PM
Creation date
11/11/2014 1:15:07 PM
Metadata
Fields
Template:
Building Department
Company Name
VALLEYDALE RO ASSOCIATION
Building Department - Doc Type
Permit
Permit #
13-14858
Building Department - Name
STREETS,DONALD N TRUST
Address
6705 ERIN CIR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� J r <br /> STEEL DECK SYSTEM LIMITATIONS: <br /> I. If inechanical attachrnent to the structural deck through the lightweight insulating concrete is proposed, a fietd <br /> withdrawal resistance testing shall be performed to determine fastener patterns and density. All testing and fastening <br /> design shall be in campliunce with Testing Apptication Standard TAS 105 and Roo£ing Application Stnndard RAS <br /> Il7 and/or RAS 137, calculations shall be signed and sealed by a Florida registered Professional Engineer, <br /> Registered Architect,or Registered Roof Consultant. <br /> 2. For steel deck application where specific deck construction is not referenced: The deck shall be a minimum 22 gage <br /> att�ched with 5/8"puddle welds with weld washers at e�•ery flute with maximum deck spans of 5 ft.o.c. <br /> GENERAL LIMITATIONS: <br /> I. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire <br /> ratings of this product. <br /> 2. Insulation�nay be installed in multiple layers. The Crst layer shal(be attached in complianec with Product Control <br /> Approvat guidelines. Atl other layers shall be adhered in a full mopping of approved asphalt applied within the <br /> EVT range and at a rate of 20-40 Ibs./sq.,or mechanically attached using the fastening pattern of the tpp layer <br /> 3. All standard panel sizes are acceprable for mechanical attachment. When applied in approved asphalt, panel size <br /> shall be 4'x�3'ma�cimum. <br /> 4. An overlay andlor recovery board insu(ation panel is required on ali applications aver closed cell foam insulations <br /> �ti�hen the base sheet is fully mopped. Ifno recovery board is used the base sheet shall be apptied using spot mapping <br /> with approved asphalt, 12" diameter circies. 24" o.c.: or strip mopped 8° ribbons in three rows, one at each sidelap <br /> and one dawn the center of the sheet atlowing a continuous areA of ventilAtion. Encircling of the strips is noi <br /> acceptabie. A 6" break shall be placed every 12' in each ribbon to allow cross ventilatioa Asphalt application of <br /> either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached svstems shall be limited to a <br /> maximum design pressure of-4S psf. <br /> 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force(F')value of 275 Ibf.,as <br /> tested in compliance with Tcsting Application Standard TAS 11)5. If the fastener value,as field-tested,arc below <br /> 27.5 Ibf. insulation att�chment shall not be acceptable. <br /> G. F�stener spacing for mechanical attachment of anchoribuse sheet or membrane attach�nent is based on a minimum <br /> fastener resistance value in con,junction with the rnaximum design value listed�vithin a specific system. Should the <br /> fAStener resistance be less than that required,as determined by the Building Official,a re��ised fastener spacing, <br /> prepAred,signed and seAted by a Florida Registered Engineer,Architect,or Registered Roof Consultant mav be <br /> submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing <br /> Applicauon Standards TAS !05 and calculations in compliance with Roo�ng Application Standard RAS 1 17. <br /> 7. Penmeter and corner areas shafl comply with the enhanced uplift pressure requirements of these areas. Fastener <br /> densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Applicution <br /> Standard RAS t 17 and/or RAS 137. (When this limitation is specificaily referred w�thin this NOA, General <br /> Limitation#9 witl not be appiieable.) <br /> �. All attachmem and sizing of perimeter nailers,metul profile,and/or#lashing tennination designs shall conforrn with <br /> Roofing Application Standard RA5 1 I 1 and applicable wind loAd requirements. <br /> ��. The rnaximum designed pressure limitation listed shAll be applicable to Alt roof pressure zones{i.e. field,perimetcrs, <br /> and corners).Neither rational analysis,nor extrapolation shall be permitted for enhAnced fastening at enhanced <br /> pressure zoncs(i.e.perimeters,extended corners and corners).(When this limitadon is specifically referred <br /> within this NOA,Gencral Limitation#7 wiU not bc applicablc.) <br /> 10. All products listed herein shall have a c�uality assurance audit in accordance with the Florida Buildin�Code and <br /> Rufe 9N-3 of the Florida Administrative Code. <br /> END OF THIS ACCEPTANCE <br /> M � tvoA rro.: 1s-aa�i.oa <br /> "'' ' Expiration Date: 08/31/14 <br /> Apprc»•al Date: 08/29/13 <br /> Page 18 of 1R <br />