Laserfiche WebLink
FORM•405-10� <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: OnTime Leah II right(4650) Builder Name: Morgancastle Studios <br /> Street: 4650 Eagle Ranch Dr Permit Office: Pasco <br /> City, State,Zip: Zephyrhills,FL, Permit Number: �t`8 (�7 <br /> Owner: Jurisdiction: �644A90 (F((l�b� <br /> Design Location: FL,Tampa <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1206.0 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Blodc-Int Insul,Exterior R=8.2 1022.70 ft2 <br /> b.Frame-Wood,Adjacent R=13.0 183.26 ft' <br /> 3. Number of units, if multiple famify 1 c.N/A R= �z <br /> 4. Number of Bedrooms 3 d�N�'°` R= ft2 <br /> 5. Is this a worst case? No 10.Ceiling Types (1295.0 sqft.) Insulation Area <br /> a.Under Attic(Vented) R=30.0 1230.00 ft' <br /> 6. Conditioned floor area above grade(ft=) 1295 b.Knee Wall(Vented) R=30.0 65.00 ftz <br /> Conditioned floor area below grade(ft') 0 c. N/A R= ft= <br /> 11. Ducts R ftz <br /> 7. Windows(115.0 sqft.) Description Area a.Sup:Attic, Ret:Attic,AH:Garage 6 259 <br /> a. U-Factor: Dbl,U=0.50 115.02 ftZ <br /> SHGC: SHGC=0.45 <br /> b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr E�ciency <br /> SHGC: a.Central Unit 25.8 SEER:14.00 <br /> c. U-Factor: N/A ft2 <br /> SHGC: 13.Heating systems kBtu/hr E�ciency <br /> d. U-Factor: N/A ft� a.Electric Heat Pump 25.5 HSPF:7.70 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 4.584 ft. <br /> Area Weighted Average SHGC: 0.450 14.Hot water systems <br /> a. Electric Cap:60 gallons <br /> 8. Floor Types (1295.0 sqft.) Insulation Area EF:0.970 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1295.00 ftz b. Conservation features <br /> b.N/A R= ft2 None <br /> c.N/A R= �2 15.Credits None <br /> Glass/Floor Area: 0.089 <br /> Total Proposed Modified Loads: 28.00 pASS <br /> Total Standard Reference Loads: 37.15 <br /> I hereby certify that the plans and specifications covered by Review of the plans and 9��1r1E 5�,�1,� <br /> this calculation are in compliance with the Florida Energy specifications covered by this _� : p <br /> Code. calculation indicates compliance y�',,���'' Z����r �,�, <br /> with the Florida Energy Code. � r,,,,,���.,;,;..4;.',,.�•;;,. `'�„� <br /> PREPARED � Before construction is completed � " " <br /> DATE: _L?__,�__�l�_'�_t 3 � _ � this building will be inspected for � j,��'• � <br /> compliance with Section 553.908 „ , <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. ,�� � <br /> with the Florida Energy Code. /� 4'��,�,�,� <br /> �� � <br /> OWNER/AGENT: _-___ __-__ _-_- BUILDING OFFI AL: <br /> DATE: _ ---- - - - DATE: - - --- <br /> - Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist <br /> 12/13/2013 11:59 AM EnergyGauge�USA-FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 5 <br />