Laserfiche WebLink
FORIV1405-10 <br /> Florida Code Compliance Checklist <br /> Florida Department of Business and Professional Regulations <br /> Residential Whole Building Pertormance Method <br /> ADDRESS: 4650 Eagle Ranch Dr PERMIT#: <br /> Zephyrhills, FL, <br /> MANDATORY REQUIREMENTS SUMMARY-See individual code sections for full details. <br /> COMPONENT SECTION SUMMARY OF REQUIREMENT(S) �' CHECK <br /> — ----�-- -- ---�- ---- — --+— - <br /> Air leakage ; 402.4 i To be caulked, gasketed, weatherstripped or otherwise sealed. ' <br /> � � Recessed lighting IGrated as meeting ASTM E 283. Windows and �I <br /> ; ,' doors=0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces i <br /> gasketed doors&outdoor combustion air. Must complete envelope , <br /> , � leakage report or visually verify Table 402.4.2. I <br /> i <br /> ------ --- - �-_ ---__-- ------------- ---- --- - --- -- ' <br /> Thermostat& 403.1 � <br /> � �� At least one thermostat shall be provided for each separate heating and I <br /> controls � cooling system. Where forced-air furnace is primary system, ,I <br /> programmable thermostat is required. Heat pumps with supplemental <br /> � i electric heat must prevent supplemental heat when compressor can i <br /> � meet the load. � <br /> -- ---- __ -�- - -----�-—------------------ ------------------ - <br /> Ducts 403.2.2 ; All ducts, air handlers, filter boxes and building cavities which form the <br /> � � primary air containment passageways for air distribution systems shall ' <br /> ! I be considered ducts or plenum chambers, shall be constructed and � <br /> � I sealed in accordance with Section 503.2.7.2 of this code. ; <br /> i <br /> _ __ _ '; a03.3.3 ; Building framing cavities shall not be used as supply ducts. � <br /> -' - ----- <br /> -— -- ------— —.._—_ -�----- <br /> _ --r---- ----- - <br /> Water heaters ; 403.4 i Heat trap required for vertical pipe risers. Comply with efficiencies in <br /> ; Table 403.4.3.2. Provide switch or clearly marked circuit breaker � <br /> ��, (electric) or shutoff(gas). Circulating system pipes insulated to= R-2 � <br /> ' + accessible manual OFF switch. � <br /> -- -- ' <br /> --- -----1— --- <br /> I � � Homes designed to operate at positive pressure or with mechanical � <br /> Mechanical i 403 5 <br /> ventilation ' i ventilation systems shall not exceed the mirnmum ASHRAE 62 level. � <br /> � i No make-up air from attics, crawlspaces, garages or outdoors adjacent ! <br /> ! � to pools or spas. ! <br /> ---- � <br /> ----�-- —..—_ _ <br /> Swimming Pools , 403.9 Pool pumps and pool pump motors with a total horsepower(HP)of= 1 � <br /> &Spas i � HP shall have the capability of operating at two or more speeds. Spas i <br /> ' I and heated pools must have vapor-retardant covers or a liquid cover or � <br /> � i other means proven to reduce heat loss except if 70%of heat from � <br /> site-recovered energy. Off/timer switch required. Gas heaters minimum <br /> ' I thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters <br /> � minimum COP=4.0. � <br /> - - ---�------�-- --- ' <br /> Coolin /heatin � 403.6 � �- <br /> 9 9 , � Sizing calculation performed &attached. Minimum efficiencies per <br /> Tables 5032.3. Equipment efficiency verification required. Special ' <br /> equipment j , occasion cooling or heating capacity requires separate system or <br /> ! j variable capaciry system. Electric heat>10kW must be divided into two I <br /> � or more stages. , <br /> --- -----�--_ ---- ' <br /> 9 R-19 space permitting. - —-- ----------------�-- ---- <br /> Ceilin s/knee walls I 405.2.1 <br /> 12113/2013 11:59 AM EnergyGauge�USA-FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 5 <br />