Laserfiche WebLink
FOR,M 405-�10 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: OnTime Leah II Builder Name: Morgancastle Studios <br /> Street: 4702 Eagle Ranch Dr Permit Office: Pasco <br /> City,State,Zip: Zephyrhills,FL, Permit Number: ( � �'`�- � <br /> Owner: Jurisdiction: ,6�19A6� (,� (( �,o� <br /> Design Location: FL,Tampa <br /> 1. New construction or existing New(From Plans) 9. Wa�l Types(1206.0 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=8.2 1022.70 ft2 <br /> b.Frame-Wood,Adjacent R=13.0 183.26 ft2 <br /> 3. Number of units,if multiple family 1 c. N!A R= ftZ <br /> 4. Number of Bedrooms 3 d.N/A R= ft2 <br /> 5. Is this a worst case? No 10.Ceiling Types (1295.0 sqft.) Insulation Area 2 <br /> a. Under Attic(Vented) R=30.0 1230.00 ft <br /> 6. Conditioned floor area above grade(ft2) 1295 b. Knee Wall(Vented) R=30.0 65.00 ft2 <br /> Conditioned floor area below grade(ft2) 0 c. N/A R= it2 <br /> 11. Ducts R ft2 <br /> 7. Windows(115.0 sqft.) Description Area a. Sup:Attic,Ret:Attic,AH:Garage 6 259 <br /> a. U-Factor: Dbl, U=0.50 115.02 ftZ <br /> SHGC: SHGC=0.45 <br /> b. U-Factor: N/A ft2 �2•Cooling systems kBtu/hr Efficiency <br /> SHGC: a.Central Unit 25.8 SEER:14.00 <br /> c. U-Factor: N/A ft' <br /> SHGC: 13. Heating systems kBtulhr Efficiency <br /> d. U-Factor: N!A ftz a.Electric Heat Pump 25.5 HSPF:7.70 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 4.584 ft. <br /> Area Weighted Average SHGC: 0.450 14.Hot water systems <br /> 8. Floor Types (1295.0 sqft.) Insulation Area a.Electric Cap:60 gallons <br /> EF:0.970 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1295.00 ft2 b. Conservation features <br /> b. N/A R= ft= None <br /> c. N/A R= �Z 15.Credits None <br /> Glass/Floor Area: 0.089 <br /> Total Proposed Modified Loads: 28.30 PASS <br /> Total Standard Reference Loads: 37.15 <br /> I hereby certify that the plans and specifications covered by Review of the plans and Q�'����T,g�,� <br /> this calculation are in compliance with the Florida Energy specifications covered by this ��. � � , p� <br /> Code. calculation indicates compliance �`�+ �,,,`'� =t;-�,.�, .�n <br /> with the Florida Energy Code. �- ,n,,,� ' ;� � ;�+�'�;, <p <br /> PREPARED . _ Before construction is completed w ��'�' _ ?' <br /> DATE: �_Z_�3_•l��-�1. .�2�,'� E?Z dc..� this building will be inspected for � � � � <br /> compliance with Section 553.908 � `��° <br /> . ������ {. <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. f,� � <br /> with the Florida Energy Code. ,� '��p yy��� <br /> OWNER/AGENT:__ _ _ -_-_ _.___--__ BUILDING CI L __-_ ___- _ <br /> DATE: _ ----._-... --- ------ - DATE: U <br /> - Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist <br /> 12/13/2013 11:56 AM EnergyGauge�USA-FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 5 <br />