Laserfiche WebLink
FORM 4�05=10 <br /> Florida Code Compliance Checklist <br /> Florida Department of Business and Professional Regulations <br /> Residential Whole Building Performance Method <br /> ADDRESS: 4702 Eagle Ranch Dr PERMIT#: <br /> Zephyrhills, FL, <br /> MANDATORY REQUIREMENTS SUMMARY-See individual code sections for full details. <br /> COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK <br /> -rt---_ �_ —- - ---------- ---�._- <br /> Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. <br /> Recessed lighting IGrated as meeting ASTM E 283. Windows and <br /> doors= 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: ', <br /> gasketed doors &outdoor combustion air. Must complete envelope ', <br /> ' leakage report or visually verify Table 402.4.2. �I <br /> ; <br /> �- - ,-_ _ __ -- -- _-_ - - _-- -- -------- -- - - --- - -�--- <br /> Thermostat& , 403.1 '� At least one thermostat shall be provided for each separate heating and '� <br /> controls � cooling system. Where forced-air furnace is primary system, <br /> I programmable thermostat is required. Heat pumps with supplemental i <br /> � electric heat must prevent supplemental heat when compressor can i <br /> ' I meet the load. <br /> - --�--- __ _____ _ <br /> fi--- ---- ---_ - - --- -- - - -- - - '�--- <br /> Ducts 403.22 I All ducts, air handlers, filter boxes and building cavities which form the � <br /> ! j primary air containment passageways for air distribution systems shall ' <br /> � be considered ducts or plenum chambers, shall be constructed and ', <br /> I sealed in accordance with Section 503.2.7.2 of this code. ! <br /> � <br /> I <br /> ; 403.3.3 ! Building framing cavities shall not be used as supply ducts. ' <br /> �� <br /> _�- � <br /> --- - - - - - _ - --- --- ____- _----- _ ---- ---- -- - -- -- � __ -_ <br /> - r- -- <br /> Water heaters I 403.4 ; Heat trap required for vertical pipe risers. Comply with efficiencies in <br /> ; � Table 403.4.3.2. Provide switch or dearly marked circuit breaker <br /> � (electric) or shutoff(gas). Circulating system pipes insulated to= R-2 <br /> ' + accessible manual OFF switch. I <br /> - - - --_ -- _T _ __ i.- -- —- _-- --------- ---- . -- - ----- -_-�----- __ <br /> Mechanical i 403.5 � Homes designed to operate at positive pressure or with mechanical <br /> ventilation ' j ventilation systems shaN not exceed the minimum ASHRAE 62 level. � <br /> No make-up air from attics, crawlspaces, garages or outdoors adjacent ; <br /> , � to pools or spas. <br /> - ----- �-- - __ __,------ - - -- - ----- =--�-- <br /> , <br /> Swimming Pools ', 403.9 �� Pool pumps and pool pump motors with a total horsepower(HP)of= 1 ; <br /> &Spas �; � HP shall have the capability of operating at finro or more speeds. Spas , <br /> ', and heated pools must have vapor-retardant covers or a liquid cover or ' <br /> � other means proven to reduce heat loss except if 70%of heat from <br /> � ;' site-recovered energy. Off/timer switch required. Gas heaters minimum ! <br /> i thermal efficiency=78% (82%after 4/16/13). Heat pump pool heaters <br /> , , minimum COP=4.0. <br /> - --- ___ -�--- ---. -r- - ------_ _ - - - ---- - -- �-- <br /> Cooling/heating I 403.6 I, Sizing calculation performed 8�attached. Minimum efficiencies per <br /> � ; Tables 503.2.3. Equipment efficiency verification required. Special <br /> equipment �!, ' occasion cooling or heating capacity requires separate system or <br /> � variable capacity system_ Electric heat>10kW must be divided into two <br /> ! ' or more stages. ' <br /> � <br /> __ --- __ ._ �_- -- --_ �- - - <br /> Ceilings/knee walls , 405.2.1 R-19 space permitting. <br /> 12/13/2013 11:56 AM EnergyGauge�USA-FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 5 <br />