My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
14-14870
Zephyrhills
>
Building Department
>
Permits
>
2014
>
14-14870
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/11/2014 1:35:39 PM
Creation date
11/11/2014 1:35:36 PM
Metadata
Fields
Template:
Building Department
Company Name
EAGLE RANCH
Building Department - Doc Type
Permit
Permit #
14-14870
Building Department - Name
KEYSTONE CHALLENGE FUND INC
Address
4620 EAGLE RANCH DR LOT 16
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FORM 405-1Q <br /> Florida Code Compliance Checklist <br /> Florida Department of Business and Professional Regulations <br /> Residential Whole Building Performance Method <br /> ADDRESS: 4620 Eagle Ranch Drive PERMIT#: <br /> Zephyrhills, FL, <br /> MANDATORY REQUIREMENTS SUMMARY-See individual code sections for full details. <br /> COMPONENT ! SECTION � SUMMARY OF REQUIREMENT(S) I CHECK <br /> � + � <br /> Air leakage � 402.4 I To be caulked, gasketed, weatherstripped or otherwise sealed. � <br /> � ! Recessed lighting IGrated as meeting ASTM E 283. Windows and , <br /> ' ; doors= 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: ! <br /> ; I gasketed doors 8�outdoor combustion air. Must complete envelope � <br /> I ; leakage report or visually verify Table 402.4.2. , <br /> _ -�----- - --- -- -- -- ---- �� - <br /> -�---- <br /> Thermostat& i 403.1 � At least one thermostat shall be provided for each separate heating and j <br /> controls ; cooling system. Where forced-air furnace is primary system, ' <br /> � programmable thermostat is required. Heat pumps with supplemental <br /> �� �, electric heat must prevent supplemental heat when compressor can � <br /> ' meet the load. _ <br /> --- -+--- � --- - -- -- --- �- --- <br /> Ducts � 403.2.2 i AII ducts, air handlers, filter boxes and building cavities which form the ; <br /> , primary air containment passageways for air distribution systems shall � <br /> � � be considered ducts or plenum chambers, shall be constructed and <br /> I sealed in accordance with Section 503.2.7.2 of this code. <br /> � I <br /> ; 403.3.3 �; Building framing cavities shall not be used as supply ducts. I <br /> -_- -- --_ �-- _---�------ _ ---- --- - - ---- ----- � - -- <br /> Water heaters �I 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in � <br /> ' � Table 403.4.3.2. Provide switch or clearly marked circuit breaker � <br /> � (electric)or shutoff(gas). Circulating system pipes insulated to = R-2 ; <br /> � + accessible manual OFF switch. ' <br /> -- - --_ - -- - - i - - --- - -- ------__ -------- <br /> � - - - _____ __ _ � _ -- <br /> Mechanical , 403.5 ; Homes designed to operate at positive pressure or with mechanical ' <br /> ventilation ! ventilation systems shall not exceed the minimum ASHRAE 62 level. I <br /> � i No make-up air from attics, crawlspaces, garages or outdoors adjacent ! <br /> � <br /> to pools or spas. �� <br /> -- ----- <br /> --— --------- <br /> - - - -- - ___ _ � - <br /> Swimming Pools ', 403.9 Pool pumps and pool pump motors with a total horsepower(HP)of= 1 � <br /> 8�Spas i �, HP shall have the capability of operating at finro or more speeds. Spas � <br /> � j and heated pools must have vapor-retardant covers or a liquid cover or i <br /> I I other means proven to reduce heat loss except if 70%of heat from ' <br /> ' site-recovered energy. Off/timer switch required. Gas heaters minimum ! <br /> ', thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters <br /> -------_�_ ._--- -- ' minimum COP=4.0. ' <br /> ---- --___ - ---------- --- ------ �----- <br /> Cooling/heating ', 403.6 Sizing calculation performed &attached. Minimum e�ciencies per , <br /> i Tables 503.2.3. Equipment efficiency verification required. Special <br /> equipment occasion cooling or heating capacity requires separate system or II <br /> variable capacity system. Electric heat>10kW must be divided into two �� <br /> � or more stages. I <br /> --- _ -f-- - <br /> -__ � __ _ _____--- ---_ __ _- - ------- - --_...-- - - ---- - -- - <br /> Ceilings/knee walls I 405.2.1 , R-19 space permitting. <br /> 12l13l2013 12:02 PM EnergyGauge�USA-FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.