Laserfiche WebLink
FOR11�405-10 ' ' <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: OnTime Corrine_Naomi right(4541) Builder Name: MorganCastle Studios <br /> Street: 4541 Eagle Ranch Drive Permit Office: Pasco <br /> City, State,Zip: Zephyrhills, FL, Permit Number: / j �?� <br /> Owner: Jurisdiction: �00��; (��LSZ� <br /> Design Location: FL,Tampa <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1373.7 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=8.2 1062.70 ftz <br /> b.Frame-Wood,Adjacent R=13.0 310.96 ft2 <br /> 3. Number of units, if multiple family 1 c.N!A R= ft= <br /> 4. Number of Bedrooms 4 d. N/A R_ �, <br /> 5. Is this a worst case? No 10.Ceiling Types (1327.0 sqft.) Insulation Area <br /> a. Under Attic(Vented) R=30.0 1287.00 ft= <br /> 6. Conditioned floor area above grade(ft') 1327 b. Knee Wall(Vented) R=30.0 40.00 ft= <br /> Conditioned floor area below grade(ft2) 0 c. N/A R= g2 <br /> 11.Ducts R ft' <br /> 7. Windows(113.4 sqft.) Description, Area a.Sup:Attic, Ret:Attic,AH:Garage 6 265.4 <br /> a. U-Factor: Dbl, U=0y 50 113.39 ftz <br /> SHGC: SHGC=0.45 <br /> b. U-Factor: N/A ffz 12-Cooling systems kBtu/hr Efficiency <br /> SHGC: a.Central Unit 28.5 SEER:14.00 <br /> c. U-Factor: N/A ft2 <br /> SHGC: 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft� a. Electric Heat Pump 28.0 HSPF:7.70 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.330 ft. <br /> Area Weighted Average SHGC: 0.450 14.Hot water systems <br /> a. Electric Cap:60 gallons <br /> S. Floor Types (1327.0 sqft.) Insulation Area <br /> EF:0.970 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1327.00 ft� b. Conservation features <br /> b.N/A R= ftZ None <br /> c. N/A R= � 15.Credits None <br /> Glass/Floor Area: 0.085 Total Proposed Modified Loads: 30.95 pASS <br /> Total Standard Reference Loads: 40.65 <br /> I hereby certify that the plans and specifications covered by Review of the plans and 9��klE ST,��, <br /> this calculation are in compliance with the Florida Energy specifications covered by this �, � �p <br /> Code. calculation indicates compliance '�!4+�,,,��''� ��R ''{',s, <br /> � � , a ,�� � <br /> with the Florida Energy Code. � :,r,,,,���„:;.;;,�;�;,,�'''„ � <br /> PREPARE : _--_ _._-__ Before construction is completed c� �0' �'� "' � <br /> DATE: . ?.��_ �snr r�.v A c� `,>: � <br /> J-Z-�-3 • _ ____� this building will be inspected for � i �• <br /> compliance with Section 553.908 � '� 'a <br /> I hereby certify that this building, as designed, is in compliance Florida Statutes. � �,�* <br /> with the Florida Energy Code. CQQ�,�„� <br /> OWNER/AGENT: -___ _. ___-_____ BUILDING OFF IAL� <br /> DATE: _.__ -_---- --- ----- DATE: _ <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory�ealed in accordance with 403.2.2.1.1. <br /> - Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist <br /> 12/13/2013 12:09 PM EnergyGauge�USA-FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 5 <br />