My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
14-14871
Zephyrhills
>
Building Department
>
Permits
>
2014
>
14-14871
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/11/2014 1:37:12 PM
Creation date
11/11/2014 1:37:09 PM
Metadata
Fields
Template:
Building Department
Company Name
EAGLE RANCH
Building Department - Doc Type
Permit
Permit #
14-14871
Building Department - Name
KEYSTONE CHALLENGE FUND INC
Address
4541 EAGLE RANCH DR LOT 24
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FORM 405-10 � <br /> . ' Florida Code Compliance Checklist <br /> Florida Department of Business and Professional Regulations <br /> Residential Whole Building Performance Method <br /> ADDRESS: 4541 Eagle Ranch Drive PERMIT#: <br /> Zephyrhills, FL, <br /> MANDATORY REQUIREMENTS SUMMARY-See individual code sections for futl details. <br /> COMPONENT I SECTION ; SUMMARY OF REQUIREMENT(S) I CHECK <br /> ------- � -- -- -- <br /> Air leakage ', 402.4 �i To be caulked, gasketed, weatherstripped or otherwise sealed. , <br /> i Recessed lighting IGrated as meeting ASTM E 283. Windows and I <br /> � doors= 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: � <br /> I gasketed doors&outdoor combustion air. Must complete envelope , <br /> ' � leakage report or visually verify Table 402.4.2. I <br /> --- - +- _ _ - 1- -------- _- - --- --- --- ------ -- ---- ---- ____ <br /> Thermostat& 403.1 � At least one thermostat shall be provided for each separate heating and i <br /> controls �, � cooling system. Where forced-air furnace is primary system, <br /> , i programmable thermostat is required. Heat pumps with supplemental <br /> , electric heat must prevent supplemental heat when compressor can <br /> _ I meet the load. � <br /> -_--------+ �--- <br /> ---- ------— ------ - ----- -_+----- <br /> Ducts ' 403.2z I All ducts, air handlers, filter boxes and building cavities which form the �� <br /> , i primary air containment passageways for air distribution systems shall I <br /> ; be considered ducts or plenum chambers, shall be constructed and i <br /> I , sealed in accordance with Section 503.2.72 of this code. i <br /> ' I <br /> 403.3.3 � Building framing cavities shall not be used as supply ducts. j <br /> --- - --- -_---- - -- - -- --- <br /> Water heaters � 403.4 � Heat trap required for vertical pipe risers. Comply with efficiencies in i <br /> � � Table 403.4.32. Provide switch or clearly marked circuit breaker <br /> � ; (electric) or shutoff(gas). Circulating system pipes insulated to= R-2 ' <br /> ; I + accessible manual OFF switch. ' <br /> -- - __- --- --� --- ----- -- - - - --- <br /> - -fi--— -- <br /> Mechanical , 403.5 Homes designed to operate at positive pressure or with mechanical <br /> ventilation � 'I ventilation systems shall not exceed the minimum ASHRAE 62 level. i <br /> � No make-up air from attics, crawlspaces, garages or outdoors adjacent ! <br /> ' � to pools or spas. � <br /> - - -�-- -� — -- - - - — ' <br /> Swimming Pools � 403.9 � Pool pumps and pool pump motors with a total horsepower(HP) of= 1 �i <br /> &Spas ; HP shall have the capability of operating at two or more speeds. Spas <br /> ' i and heated pools must have vapor-reta�dant covers or a liquid cover or I <br /> j , other means proven to reduce heat loss except if 70%of heat from ' <br /> ' site-recovered energy. Off/timer switch required. Gas heaters minimum ', <br /> � � thermal efficiency=78% (82%after 4/16/13). Heat pump pool heaters ; <br /> � ' minimum COP=4.0. ; <br /> ------ ;-- ----+--- — �_._ <br /> Cooling/heating , 403.6 i Sizing calculation performed &attached. Minimum efficiencies per � <br /> i ; Tables 5032.3. Equipment efficiency verification required. Special <br /> equipment occasion cooling or heating capacity requires separate system or <br /> j ��, variable capacity system. Electric heat>10kW must be divided into finro � <br /> � or more stages. ; <br /> --- ---- - <br /> � — ---� - -- -- - <br /> Ceilings/knee walls ! 405.2.1 � R-19 spaCe permitting. ' <br /> 12/13/2013 12:09 PM EnergyGauge�USA-FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.