My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
14-14872
Zephyrhills
>
Building Department
>
Permits
>
2014
>
14-14872
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/11/2014 1:39:39 PM
Creation date
11/11/2014 1:39:36 PM
Metadata
Fields
Template:
Building Department
Company Name
EAGLE RANCH
Building Department - Doc Type
Permit
Permit #
14-14872
Building Department - Name
KEYSTONE CHALLENGE FUND INC
Address
4614 EAGLE RANCH DR LOT 17
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FORM 405-10 <br /> Florida Code Compliance Checklist <br /> Fiorida Department of Business and Professional Regulations <br /> Residential Whole Building Performance Method <br /> ADDRESS: 4614 Eagle Ranch Drive PERMIT#: <br /> Zephyrhills, FL, <br /> MANDATORY REQUIREMENTS SUMMARY-See individual code sections for full details. <br /> COMPONENT I SECTION li, SUMMARY OF REQUIREMENT(S) ', CHECK <br /> , <br /> _-'� - - --- - - - --- ___ . ------- <br /> � <br /> Air leakage ' 402.4 ', To be caulked, gasketed, weatherstripped or othe►wise sealed. <br /> ' Recessed lighting IGrated as meeting ASTM E 283. Windows and , <br /> ' doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: ', <br /> ' gasketed doors 8�outdoor combustion air. Must complete envetope ', <br /> ' leakage report or visually verify Table 402.4.2_ I <br /> - _ ----- -- - - � _ _- - _ _ ------- __ _ - <br /> Thermostat& ' a03.1 ! At least one thermostat shall be provided for each separate heating and <br /> controls ' ' cooling system. Where forced-air furnace is primary system, ', <br /> ! programmable thermostat is required. Heat pumps with supplementai <br /> I ' electric heat must prevent supplemental heat when compressor can , <br /> , ' meet the load. <br /> _ ;-- __--_ _ _ <br /> -- _ _ _ _-- _ __ --- -- --- ___ . _ � -- - <br /> Ducts , 40322 ' All ducts, air handlers, filter boxes and building cavities which form the <br /> ' primary air containment passageways for air distribution systems shall <br /> ' I be considered ducts or plenum chambers, shall be constructed and <br /> � sealed in accordance with Section 503.2.7.2 of this code. I� <br /> i ' <br /> I 403.3.3 ', Building framing cavities shall not be used as supply ducts. i <br /> � _ -_ -- - - -- ---�_ <br /> — - �__ __ _�------ --- <br /> water heaters ; 403.4 , Heat trap required for verticat pipe risers. Comply with efficiencies in ' <br /> Table 403.4.3.2. Provide switch or clearly marked circuit breaker <br /> ', (electric)or shutoff(gas). Circulating system pipes insulated to= R-2 ' <br /> + manual OFF switch. <br /> accessible <br /> ' , _ _-__ __-_. -- <br /> ---- --_ _ <br /> - _ .-----_ _------ <br /> — -- I ---- . 9 P P � P <br /> Mechanical , 403.5 Homes desi ned to o erate at ositive ressure or with mechanical <br /> ventilation , , ventilation systems shall not exceed the mmimum ASHRAE 62 level. <br /> ' I No make-up air from attics, crawlspaces, garages or outdoors adjacent I, <br /> ' ', to pools or spas. , <br /> ---- -- --------�-- <br /> Swimming Pools 4.9 ? Pool pumps and pool pump motors with a total horsepower(HP) of= 1 ' <br /> &Spas I ; HP shall have the capability of operating at finro or more speeds. Spas , <br /> � and heated pools must have vapor-retardant covers or a liquid cover or , <br /> � other means proven to reduce heat loss except if 70%of heat from ' <br /> ' I site-recovered energy. Off/timer switch required. Gas heaters minimum � <br /> � ', thermal efficiency=78% (82%after 4/16/13). Heat pump pool heaters <br /> minimum COP=4.0. � <br /> ------�- -___—r. <br /> _ _ _. _ _ - -- -- -- ----_�-— - <br /> Cooling/heating ' 403.6 � Sizing calculation performed &attached. Minimum efficiencies per ' <br /> Tables 5032.3. Equipment efficiency verification required. Special ' <br /> equipment occasion cooling or heating capacity requires separate system or <br /> ' variable capacity system. Electric heat>10kW must be divided into two <br /> , or more stages. <br /> ._- _ _—__ . <br /> _ r-- _- <br /> Ceilings/knee walls �� 4052.1 � R-19 spaCe pet'mitting. '' <br /> 12/13l2013 12:05 PM EnergyGauge�USA-FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.