My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
14-14872
Zephyrhills
>
Building Department
>
Permits
>
2014
>
14-14872
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/11/2014 1:39:39 PM
Creation date
11/11/2014 1:39:36 PM
Metadata
Fields
Template:
Building Department
Company Name
EAGLE RANCH
Building Department - Doc Type
Permit
Permit #
14-14872
Building Department - Name
KEYSTONE CHALLENGE FUND INC
Address
4614 EAGLE RANCH DR LOT 17
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FORM�405-10 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: OnTime Corrine_Naomi right(4614) Builder Name: MorganCastle Studios <br /> Street: 4614 Eagle Ranch Drive Permit Office: Pasco <br /> City,State,Zip: Zephyrhills, FL, Pertnit Number. j�{J�Z <br /> Owner: Jurisdiction: fi�996� (p(�(pC� <br /> Design Location: FL,Tampa <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1373.7 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=82 1062.70 ft' <br /> b. Frame-Wood,Adjacent R=13.0 310.96 ft2 <br /> 3. Number of units,if multiple family 1 c.N!A R= ft2 <br /> 4. Number of Bedrooms 4 d.N/A R_ �: <br /> 5. Is this a worst case? No 10.Ceiling Types (1327.0 sqft.) Insulation Area � <br /> a. Under Attic(Vented) R=30.0 1287.00 ft <br /> 6. Conditioned floor area above grade(ftZ) 1327 b. Knee Wall(Vented) R=30.0 40.00 ftZ <br /> Conditioned floor area below grade(ft2) 0 c. /A R= <br /> 2 <br /> 11. Ducts R ft' <br /> 7. Windows(113.4 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Garage 6 265.4 <br /> a. U-Factor: Dbl, U=0.50 113.39 ft' <br /> SHGC: SHGC=0.45 <br /> b. U-Factor: N/A ft2 �2.Cooling systems kBtulhr Efficiency <br /> SHGC: a.Central Unit 28.5 SEER:14.00 <br /> c. U-Factor: N/A ft' <br /> SHGC: 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ftz a.Electric Heat Pump 28.0 HSPF:7.70 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.330 ft. <br /> Area Weighted Average SHGC: 0.450 14.Hot water systems <br /> 8. Floor Types (1327.0 sqft.) Insulation Area a.Electric Cap:60 gallons <br /> EF:0.970 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1327.00 ftZ b. Conservation features <br /> b. N/A R= ft2 None <br /> c. N/A R= ftz 15.Credits None <br /> Total Proposed Modified Loads: 30.95 pASS <br /> Glass/Floor Area: 0.085 <br /> Total Standard Reference Loads: 40.65 <br /> I hereby certify that the plans and specifications covered by Review of the plans and ��lr1E S�,q�, <br /> this calculation are in compliance with the Florida Energy specifications covered by this ��.Q�� � �,`�p� <br /> Code. calculation indicates compliance ��+ �,,, ' , :r;'���+� �s+ <br /> with the Florida Energy Code. h' ,�n,r "�„ •;',=.i. ,,••';,�� '�a„'��? <br /> PREPARED '- _-__ _ Before construction is completed � ,�, �` " o <br /> DATE: �-1.3'_�t� ___ �_ this buitding will be inspected for � �,�� � <br /> compliance with Section 553.908 „ �° ,� <br /> I hereby certify that this building, as designed, is in compliance Florida Statutes. �,� �� <br /> with the Florida Energy Code. �'QL?WE`'�� <br /> OWNER/AGENT BUILDING �FFI IAL' __ __ - __ ____ <br /> DATE: --- --- --- --_- __ _ _ -_ DATE: - � --_-.- - - ----- <br /> - Compliance requires certiFcation by the air handler unit manufacturer that the air handler enclosure qua ies as <br /> certified factory�ealed in accordance with 403.2.2.1.1. <br /> - Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist <br /> 12/13/2013 12:05 PM EnergyGauge�USA-FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.