Laserfiche WebLink
Project:2013577 <br /> Title:The Commons on Pretty Pond <br /> Type:Dormitory <br /> (WEA File:FL TAMPA INTERNATIOIYAL AP.tm3) <br /> System Report Compliance <br /> System 1 System 1 Constant Volume Air Cooled No.of Units <br /> Split System<65000 Btu/hr 7 <br /> Component Category Capacity Design Eff Design IPLV Comp- <br /> Eff Criteria lPLV Criteria liance <br /> Cooling System Air Conditioners Air Cooled 15.10 12.23 8.00 PASSES <br /> Split System<65000 Btu/h <br /> Cooling Capacity <br /> Heating System Electric Furnace 1.00 1.00 PASSES <br /> Air Handling Air Handler(Supply)- 0.80 0.82 PASSES <br /> System-Supply Constant Volume <br /> System 2 System 2 Constant Volume Air Cooled No.of Units <br /> Split System<65000 Btu/hr 3 <br /> Component Category Capacity Design Eff Design IPLV Comp- <br /> E17' Criteria lPLV Criteria liance <br /> Cooling System Air Conditioners Air Cooled 15.10 12.23 8.00 PASSES <br /> Split System<65000 Btu/h <br /> Cooling Capacity <br /> Heating System Electric Furnace 1.00 1.00 PASSES <br /> Air Handling Air Handler(Supply)- 0.80 0.82 PASSES <br /> System-Supply Constant Volume <br /> System 3 System 3 Constant Volume Air Cooled No.of Units <br /> Split System<65000 Btu/hr 1 <br /> Component Category Capacity Design Eff Design IPLV Comp- <br /> Eff Criteria lPLV Criteria liance <br /> Cooling System Air Conditioners Air Cooled 15.10 12.23 8.00 PASSES <br /> Split System<65000 Btu/h <br /> Cooling Capacity <br /> Heating System Electric Furnace 1.00 1.00 PASSES <br /> Air Handling Air Handler(Supply)- 0.80 0.82 PASSES <br /> System-Supply Constant Volume <br /> System 4 System 4 Constant Volume Air Cooled No.of Units <br /> Split System<65000 Btu/hr 1 <br /> Component Category Capacity Design Eff Design IPLV Comp- <br /> Eff Criteria lPLV Criteria liance <br /> EnergyGauge Summit�FlalCom-2010.Section 506.4 Compliant Software.Effective Date:March 15,2012 <br /> 10/14/2013 Page 6 of 10 <br />