STEEL DECK SYSTEM LIM[TATIONS: <br /> (. If inechanical attachment to the structural deck through the lightweight insulating concrete is proposed, a field <br /> �vithdrawal resistance testing shal(be performed to determine fastener patterns and density. All testinb and fastening <br /> design shall be in compliance with Testing ApplicAtion Standard TAS 105 and Roofing Application Standard RAS <br /> 117 andlor RAS 137, calculations shall be signed and sealed by a Florid� registered Professional Engineer, <br /> Registered Architect,or Registered Roof Consultant. <br /> ?. For steel deck application where specific deck construction is not referenced: The deck shall be a minrmum 22 gage <br /> att�ched with 5!R"puddle welds�uith weld washers at e��ery flute with maximum deck spans of 5 ft.o.c. <br /> GENERAL LIMI?ATIONS: <br /> l. Fire classification is not part of this acceptance, refer to a current Approved Roafing Ntaterials Directory for fire <br /> ratings of this product. <br /> 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product C'ontrol <br /> Approval guidelines. All other layers shal( be adhered in a full mopping of approved asphalt applied within the <br /> EVT range and at a rate of 20-�30 lbs./sq.,or mechanically attached using the fastening pattern of the top layer <br /> 3. All standard pancl sizes are acceptable for mechanical attachment. When app(ied in approved asphalt, panel size <br /> shall be 4'x 4'maximum. <br /> 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations <br /> �vhen the base sheet is fuliy mopped. If no recovery board is used the base sheet shali be applied using spot mopping <br /> with approved asphalt, t Z" diameter circles, 2�1" o.c.:or strip mopped 8" ribbons in three rows, o�ie at each sidelap <br /> and one down the center of the sheet allowing a continuous areA of ventilation. Encircling of the strips is not <br /> acceptabte. A (" break shall be placed every 12' in each ribbon to allow cross ventitation. Asphalt application of <br /> either system sha(I be at a minimum rate of 12 Ibs.�'sq. Note: Spot attached systems shall be limited to a <br /> maximum desi�n pressure of-4S psf. <br /> 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force(F')value of 2�_5 IbC.,as <br /> tested in compliance with Testing Application Standard TAS 105, If the fastener value,as�eld-tcstcd,are belo�v <br /> 275 lbf. insulation attachment shall not be acceptable. <br /> G. F�stener spacing for mechanical attachment of anehorlbase sheet or membrane attachment is based on a minimum <br /> fastener resistance value in conjunction w�ith the maximum desi�m value listed within a specific system. Should the <br /> fastener resistance be less than that required,as determined by the Building Official,a re��ised fastener spacing, <br /> prepared,signcd and sealed by a Florida Registered Engineer,Architect,or Registered Roof Consultant mav be <br /> submiued. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing <br /> Application Standards TAS FOS and calculations in compliance with Roofing Application Standard RAS 1 l7. <br /> 7. Perimeter and corner areas shall comply w�ith the enhanced uplitt pressure requirements of these areas. Fastener <br /> densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application <br /> StAndard RAS 117 andlor RAS 137. (When this limitation is specifically referred within this NOA, General <br /> Limitation#9 wi11 n�t be anplicable.) <br /> K. All auachment and sizing of perimeter nailers,metal profile,andlor flashing termination designs shall conform with <br /> Raofing Application Standard RAS 1 11 and applicable wind load requirements. <br /> 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones(i.e. field,perimeters, <br /> and corners).Neither rational analysis,nor extrapolation shall be permitted for enhanced fastening at enhanced <br /> pressum zanes(i.e.perimeters,extended corners and corners).(When this limitation is specifically referred <br /> within this NOA�Cenerxl Limitation#7 will not be��plicablc.) <br /> 1t1. All products listed herein shatl have a quality assurance audit in accordance with the Florida Building Code and <br /> Ruie 9N-3 of the Florida Administratiti�e Code. <br /> END OF TNIS ACCEPTANCE <br /> M1A ECOUNTY NOA No.: 13-0411.04 <br /> ''"'• ►� Expiration Date: 08/31/14 <br /> Approval Date: ()8/29/13 <br /> Pa�e lA af IR <br />