My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
14-14953
Zephyrhills
>
Building Department
>
Permits
>
2014
>
14-14953
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/12/2014 9:10:57 AM
Creation date
11/12/2014 9:10:57 AM
Metadata
Fields
Template:
Building Department
Company Name
GRAND HORIZONS
Building Department - Doc Type
Permit
Permit #
14-14953
Building Department - Name
SULLINS III CHARLES V REV TR
Address
37638 LORENA AVE LOT 126
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
,.,-�__`-, <br /> -- -�:- —,_-��_ <br /> i ti--"" "" ' I + {�_� - --,__�--_'`� <br /> � � � � ' <br /> I ; � � i <br /> ! i Force Engineering&Tesring Inc. , i <br /> �-' 19530 Ramblewuud Drive �`-� <br /> HumVIe,TX 77338 <br /> Code Compliance: The product described herein has demonstrated compiiance with <br /> The Florida Building Code 2010,Section 15043.2,1504.7. <br /> Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load <br /> requirements of the Florida Building Code 2010,as relates to Rule 9N-3. <br /> Performance Standards: The product described herein has demonstrated compliance with: <br /> ■ UL 580-06-Test for Uplift Resistance of Roof Assemblies <br /> ■ UL 1897-04-Uptift Test for Roof Covering Systems <br /> • FM 4471,Section 5.4-Foot Traffic Resistance Test <br /> Reference Data: 1. UL 580-94/1897-98 Uplift Test <br /> Force Engineering&Testing,Inc.{FBC Organization#TST-5328) <br /> Report No. 117-00407T-09,Dated 11J16/09 <br /> 2. FM 4471-95,Section 5.4 Foot Traffic Resistance Test <br /> Force Engineering&Testing,Inc.(FBC Organization#TST-5328) <br /> Report No. 117-0238T-09E,Dated 07J21/20d9 <br /> 3. Certificate of Independence <br /> By Terrence E.Wolfe,P.E.(No.44923)@ Force Engineering&Testing,Inc. <br /> (FBC Organization#ANE ID: 1920) <br /> Test Standard Equivalency: 1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard. <br /> 2. The UL 1897-98 test standard is equivalent to the UL 1$97-04 test standard. <br /> Quality Assurance Entity: The manufacturer has established compliance of roof panel products in <br /> accordance with the Florida Building Code and Rule 9N-3.005(3)for <br /> manufacturing under a quality assurance program audited by an approved <br /> quality assurance entity. <br /> Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2010,including Section <br /> 1507.4.2 and in accordance with Manufacturers recommendations. For slopes <br /> less than 3:12, lap sealant must be used in the panel side laps. <br /> Installation: Install per manufacturer's recommended details. <br /> Underlayment: Per Manufacturer's installation guidelines per Florida Building Code 2010 Section <br /> 1507.4.5. <br /> ,`���{ff1lllll/�� <br /> `t�� �;N•C E' E•�,0 �iI <br /> i <br /> `�t�,Q.•�' � C E N s F �,��i <br /> � ` . No.4R,�� �' :c",~ �-•���, <br /> � ' �, ,-� c <br /> � %�,� � R ykt�-. � � . •* ' -. <br /> `, �4'-1i��_9-_ . � <br /> � � ,' <br /> �,'�' STATE OF :a'' <br /> i�'�' c� '' <br /> ♦ <br /> ;°�`F FL o R x ��' ���'; <br /> �"""' ,����,�4 N AL.� 4'����� <br /> ����1111f1►�\ <br /> �i,#ii6s1.2�[ti February 22, 2012 <br />
The URL can be used to link to this page
Your browser does not support the video tag.