My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
14-14977
Zephyrhills
>
Building Department
>
Permits
>
2014
>
14-14977
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/12/2014 9:26:25 AM
Creation date
11/12/2014 9:26:23 AM
Metadata
Fields
Template:
Building Department
Company Name
VALLEYDALE RO ASSOCIATION
Building Department - Doc Type
Permit
Permit #
14-14977
Building Department - Name
MORRIS,PETER FRANCIS
Address
6746 SUNNIDALE DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� <br /> �� " 97205.02-501-47 <br /> Architectural Testing Page4of6 <br /> Test Specimen Description: (Continued) <br /> Reinforcement: The lock rail contained a custom-shaped, formed steel reinforcement, <br /> reference Drawing No. UY0095. The exterior meeting rail, all sash stiles, and bottom rail <br /> contained a custom-shaped, formed steel reinforcement, reference Drawing No. UY0094. <br /> Installation: The unit was installed in a wood buck constructed of Spruce-Pine-Fir <br /> construction lumber and secured through the jambs using four #8 x 2-1/2" long screws, one <br /> at the top and bottom of each jamb. The exterior and interior perimeter was sealed with a <br /> silicone sealant, with the exception of an approximate 4" long void at each interior sill <br /> corner. A nominal 1/8" gap was maintained at the perimeter between the buck and window <br /> frame. <br /> Test Results: The temperature during testing was 67° F. The results are tabulated as follows: <br /> Para r�aph Title of Test- Test Method Results Allowed <br /> 1.4.2.1 Structural Performance Test per ASTM E 330 <br /> (Loads were held for 10 seconds) <br /> 1.4.2.1.1 25.0 psf(positive) No damage No damage <br /> 1.4.2.1.2 12.5 psf(negative) No damage No damage <br /> 1.4.2.2 Air Infiltration Test per ASTM E 283 <br /> 1.57 psf(25 mph) 0.13 cfm/ft2 0.5 cfm/ft2 max. <br /> 1.423 Water Resistance Test per ASTM E 547 <br /> (with and without insect screen) <br /> 2.86 psf No leakage No leakage <br /> AAMA 1704-01: <br /> 3.1.1 Clear opening width 31-5/8" 20" <br /> 3.1.2 Clear opening height 32-3/4" 24" <br /> 3.1.3 Clear opening area 7.2 ft2 5.0 ft2 <br /> 3.2.1 Locks and latches 4 lbf 20 Ibf <br /> 3.2.2 Operable sash 16 lbf 20 lbf <br /> 3.2.3 Removable screen 4 lb 5 lb <br />
The URL can be used to link to this page
Your browser does not support the video tag.