Laserfiche WebLink
_- -_T; __ <br /> ' .�—` ��__ -�-_ <br /> _— -__ ,-,. _. ,.._, <br /> I\4�� � ���� <br /> � �I � ` �I{� <br /> � �� Force Engineering& Testing Inc. ��, i <br /> L� Li' <br /> 19530 Ramblcwuud Drive <br /> Humble,T7�77338 <br /> Code Compliance: The product described herein has demonstrated compliance with <br /> The Florida Building Code 2010,Section 1504.3.2,1504.7. <br /> Evaluation Report 5cope: The product evaluation is limited to compliance with the structural wind load <br /> requirements of Yhe Florida Building Cade 2010,as relates to Rule 9N-3. <br /> Performance Standards: The product described herein has demonstrated compliance with: <br /> • UL 580-06-Test for Uplift Resistance of Roof Assemblies <br /> • UL 1897-04-Uplift Test for Roof Covering Systems <br /> ■ FM 4471,Section 5.4-Foot Traffic Resistance Test <br /> Reference Data: 1. UL 580-94/1897-98 Up�ift Test <br /> Force Engineering&Testing,Inc.(FBC Organization#TST-5328) <br /> Report No. 117-00407T-09,Dated 11/16/09 <br /> 2. FM 4471-95,Section 5.4 Foot Traffic Resistance Test <br /> Force Engineering&Testing,Inc.(FBC Organization#TST-5328) <br /> Report No. 117-0238T-09E,Dated 07/21/2009 <br /> 3. Certificate of Independence <br /> By Terrence E.Wolfe,P.E.(No.44923)@ Force Engineering&Testing,Inc. <br /> (FBC Organization#ANE ID: 1920) <br /> Test Standard Equivalenty: 1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard. <br /> 2. The UL 1897-98 test standard is equivalent to the UL 1897-04 test standard. <br /> Quality Assurance En#ity: The manufiacturer has established compliance of roof panel products in <br /> accordance with the Florida Building Code and Ru�e 9N-3.005(3)for <br /> manufacturing under a quality assurance program audited by an approved <br /> quality assurance entity. <br /> Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2010,including Section <br /> 1507.4.2 and in accordance with Manufacturers recommendations. For slopes <br /> less than 3:12,lap sealant must be used in the panel side laps. <br /> Installation: Install per manufacturer's recommended details. <br /> Underlayment: Per Manufacturer's installation guidelines per Florida Building Code 201Q Section <br /> 1507.4.5. <br /> +`���{ttl!/�t�,' <br /> �i�� ��•c E' ���'p ��i <br /> ; Q:�� � C E IY s� ��i� <br /> ` �`V• No.414,�3'� ,��~i r .'{", <br /> . <br /> i • ' *. .�y -.�F <br /> ��?,��4'.,�,. iq �_T. .*��_ :* --� <br /> V " „'• STAI'E OR :�+' <br /> . 7+'. <br /> . <br /> �,�, '-�F FL �Rx v�';���,•' <br /> i�iDCne ,,��f����1►i����,� <br /> FI,#11651.27 Rl <br /> February 22, 2012 <br />