Laserfiche WebLink
, , � <br /> FORM 405-10 <br /> FLt'JRIDA ENERGY EFFIClENC`�f C4DE FOR BU[LD[NG CONSTRUCTION <br /> fiorida Department of Business and Professional Regulation - Resident[al Performance Methad <br /> Project Name: The Concord II 1445 Builder Neme:IH Central Florida, LLC <br /> Street: 36207 Shady Bluff Loop Permit otrce: City of Zephyrhilis <br /> Ctty,state,Zip:Zephyrhilis, FL 33541 Permit Number. Q <br /> Owner.IH Central Florida, LLC Jurisdtction: G;((/(Q pa <br /> Design Location: FL,Tampa <br /> I1. New Construction or existing New(From Plans) 9. Wall Types(1399.9 sqftJ Insulatlon Area <br /> 2. Single famly or multlpie famfly Single-famlly a.Concrete Block-Int Insul,Exterior R=4.1 1711.90 ft= <br /> b.Frame-Wood,Ad�ecent R=11.D 288.00 ft' <br /> ( 3. Number of units,if multiple family 1 ��p <br /> 4. Number of Bedrooms 3 d.N/A R= ft <br /> 5. ts this a worst case? No 10.Ceiling Types {i584.0 sqR.) Insulation Area <br /> a.Under Attic(Vented) R=30.0 1461.00 ft� <br /> 6. Condit[oned floor area above grade(ft') 1445 b.Knee Wall(Vented) R=19.0 123.00 ft' <br /> � Conditioned ifoor area beiow grade(ft� 0 c.N/A R= fF <br /> 11.Qucts R iN <br /> � 7. Wfndows(178.3 sqft.) Description Ares a.5up:Attic,Ret:Entire Structure,AH�Entire Struct 8 289 <br /> a. U-Factor: Dbl,U=0.56 t79.29 ft' <br /> I SHGC: SHGG=0.37 <br /> b. U-Factor: N/A ftz �2•Cooling systems kBtulhr Efflciency <br /> SHGC: a.Central Unit 23.2 SEER:14.00 <br /> c. U-Factor: WA ft= <br /> SHGC: 13.Fleating sysfems kBtu/tir Efficfency <br /> d. U-Factor; N/A ft� a. Electdc Heat Pump 22.6 HSPF:8.00 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.000 ft. <br /> Arae Welghted Average SHGC: 0.370 14.Mot watar syslems <br /> 8. Floor Typas (144G.0 sqft.) Insulation Area e.Efoctrfc Cap:40 gallons <br /> � a.Sleb-On-Grade Edge Insuiation R=0.0 1445.00 fta EF:0.920 <br /> b. Conservation features <br /> b.N/A R= fN None <br /> ; c.N/A R= ft� <br /> 15.Gredits Pstat <br /> i <br /> � Tota) Proposed Modified Loads: 31,78 <br /> Glass/Floor Area: O.�t24 Total Standard Reference Laads: 40.43 PASS <br /> I hereby certify that the plans and speciflcations covered by Review of the plans and ���TifE S�„� <br /> this calculation are in compliance with the Fiorida Energy speciflcations covered by this ,� p <br /> Code. � calculation indicates compllance �'�i '� � �a'�'��s±+ <br /> with the Florida Energy Code. � urn�. tr ''yixg "� `� C3 <br /> ' PREPARED BY: eefare constnaction is cflmpleted , � <br /> DA7"E: ..,.�` ��__._ _ ._. this butiding will be inspected for � -'��;��:� y; <br /> compliance with Section 653.905 ,� <br /> I hereby certify that this bullding,as designed,is fn compliance �orida Statutes. �� <br /> with the Florida Energy Code � pA�,�g'� <br /> OWNER/AGENT:---- ._. ___ .�_� 6UILDING OFFICIAL: _---.. _`_ � _.... ___. <br /> OATE: _�._��L2-�.._ _._ �---- DATE: �.=.Z�1�L�.-•-=..- -.------..._ <br /> - Compliance requires certiflcation by the alr handlar unit manufacturer that tlte atr handler enclosure qualifles as <br /> certified factory-soafed in accordance with d03.2.2.1.1, <br /> - Compiiance requlres completion of a Flortda Air BarNer and Insulation InspecNon Checkl[st <br /> •Heatsys#1 may be undarsized.Size of 22.6 was Increasad to 24.8 for simulation, Please revlew the Manual J8 report.-Cool sys <br /> #1 may be undsrsizad.8ize of 23.2 was increased to 23.2 for simulation, Please revlow the Manual J$report. <br /> 4/8/2013 2:40 PM EnergyGauge�USA-FlaRes2010 SecNon 405.4.1 Compllant Software Page 1 of 6 <br /> I <br />