My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
14-14990
Zephyrhills
>
Building Department
>
Permits
>
2014
>
14-14990
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/12/2014 9:34:25 AM
Creation date
11/12/2014 9:34:22 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
14-14990
Building Department - Name
IH CENTRAL FLORIDA LLC
Address
36207 SHADY BLUFF LP LOT 110
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FORM 405-10 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> ' Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: The Concord il 1445 Builder Name: <br /> Street; Permit Office: <br /> City,State,Zip: TAMPA,FL,33625- Permit Number: <br /> Owner; Inland Homes Jurisdiction: <br /> Deslgn Location: FL,Tampa <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1399.9 sqft.) Insulation Area <br /> 2. Single family or multiple family Singls-family a.Concrete Block-Int Insul,Exterior R=4.1 1111.90 ft' <br /> 3. Number of units,if multiple family � b.Frame-Wood,Adjacent R=11.o 288.00 ft2 <br /> c.N!A R= ftZ <br /> 4. Number of Bedroams 3 d.N/A R= ft' <br /> 5. Is this a worst case? No 10.Cetling Types (1584.0 sqft.) Insulation Area <br /> a.Under Attic(Vented) R=30.0 1461.00 ftZ <br /> 6, Conditioned floor area above grade(ftZ) 1445 b.Knee Wall(Vented) R=19.0 123.00 ft= <br /> Conditioned floor area below grade(ft') p c.N/A R= ft2 <br /> 7. Windows(178.3 sqft.) Description Area ��•Ducts R ft' <br /> a.Sup:Attic,Ret:Entire Structure,AH:Entire Struct 6 289 <br /> a. U-Factor: Dbl,U=0.56 �7g.2g�= <br /> SHGC: SHGC=0.37 <br /> b, U-Factor: N/A ft= 12.Cooling systems kBtu/hr E�ciency <br /> SHGC: a.Central Unit 23.2 SEER:14.00 <br /> c. U-Factor: N/q ft, <br /> SHGC: 13.Heatin s stems <br /> d. U-factor: N/q ft, 9 y kBtulhr Efficiency <br /> SHGC: <br /> a.Electrtc Heat Pump 22.6 HSPF:8.00 <br /> Area Weighted Average Overhang Depth: 1.000 ft. <br /> Area Weighted Average SHGC: 0.370 14.Hot water systems <br /> 8. Floor Types (1445.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> a.Slab-On-Grade Edge Insulation R=0.0 1445.00 ftz b. Conservation features �F:0.920 <br /> b.N/A R= ftZ None <br /> c.N/A R= ft2 <br /> 15.Credits Pstat <br /> Glass/Floor Area: 0.124 Yotal Proposed Modified Loads: 31.78 pqSS <br /> Total Standard Reference Loads: 40.43 <br /> I hereby certify that the plans and specifications covered by Review of the plans and Q.�TBESp,�T� <br /> this calculation are in compliance with the Florida Energy specifications covered by this �,y 0 <br /> Code. calculation indicates compliance y'c�rH,y'' _=,,.-;r�o � <br /> with the Florida Energy Code. F, rru,,.. �,, �'•.�;,,'` �p <br /> PREPARED BY: __ _ _ Before construction is completed r� � �� � <br /> DATE: �'�,�� •, <br /> - _ this building will be inspected for � ,�;�y;� �, <br /> compliance with Section 553.908 , '" � n <br /> I hereby certify that this building,as designed,is in compliance Florida Statutes. , ,j� � � <br /> with the Florida Energy Code. �,��, <br /> OWNEWAGENT: -_. BUILDING OF6�CI�/�,; �' % <br /> DATE: DATE: �� <br /> _-----------..----- - <br /> ---_ ---t- -- <br /> • - Compl(ance requires certiflcation by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with 403.2.2.1.1. <br /> - Compliance requlres completion of a Florida Air Barrler and Insulation(nspectlon Checklist <br /> -Heat sys#1 may be undersized.Size of 22.6 was increased to 24.9 for simulatlon.Please review the Manual J8 report.-Cool sys <br /> #1 may be undersized.Size of 23.2 was increased to 23.2 for simulation.Please review the Manual J8 report. <br /> 4/8/2013 2:41 PM EnergyGauge�USA-FlaRes2010 Secifon 405.4.1 Compliant Software Page 1 of 6 <br /> � <br />
The URL can be used to link to this page
Your browser does not support the video tag.