, ' 1 <br /> FORM 405-10 F�orida Code Compliance Checklist <br /> Fiorida Department of Business and Professianal Regulations <br /> Residential Whole Building Performance Methoci <br /> ADDRESS PERMIT# <br /> DADE CITY, F�, 33525- . <br /> �~� MANDATORY REQ�IREMENTS SUMMARY-See individual code sections for full detaiis. <br /> CQMPONENT SECTION SUMMARY OF REQUiREMENT{S) CHECK <br /> Air leakage 402.4 To be caulked, gaske#ed, weathersiripped or other�+ise sealed. <br /> Recessed lighting IGrated as meeting ASTM E 283 Windaws and <br /> doors = 0.30 cfnitsq.ft. Testing or v�sual inspection required. Fireplaces <br /> gasketed doors &outdoor combustion air Must complete envelope <br /> leakage report or visualay verify Table 402 4.2 <br /> Thermostat 8 a�3.� At least one thermostat shall be provided for each separate heating and <br /> contro�s cooling system. Where forced-air furnace is primary system, <br /> programmabie thermosTat is requlred Neat pumps with supplemental <br /> electric heat must prevent supplementai heat when compressor can <br /> meet the foad. <br /> Ducts a03.2.2 All duets, air handlers, filter boxes and buliding cavities which form the <br /> primary air containment passageways for arr distnbution systerns shall <br /> be consadered ducts or plenum chambers. sliali be constructed and <br /> sealed in accardance with Section 503.2.7,2 of th�s code. <br /> 403.3.3 Suilding framing cavities shali not be used as supp(y ducts <br /> f , Water heatcrs � 403.4 Heat trap required for verticai pipe risers Comply with efficiencies in <br /> Table 403.4.3.2. Provide switch or clearly marked circu�t breaker <br /> (electric} or shukQff{gas7 Circulating system pipes insu�ated to = R-2 <br /> + accessible manual OFF switch <br /> Mechanical 403.5 Homes designed to operate at pasiUve pressure or with mechan�cal <br /> ventilatian ventilation systems shall not exceed the minimum ASHRAE 62 level <br /> No make-up air from attics, crawlspaces, garages or outdoars adjacent <br /> to poois or spas. <br /> Swimm,ng Poois a03.9 Poo! pumps and pooi pump motors with a total horsepawer {HP} of= 1 <br /> & Spas HP shall have the capability of operating at two or more speecis Spas <br /> and heated pools must have vapor-retardant covers or a 6qu�d cover or <br /> other means proven to reduce heat loss except if 7Q°la of heat frorn <br /> site-recovered energy. Of#ltimer switch required Gas heaters minimum <br /> iherr�al efficiency-78°fo (82°lo after 4,r1�113) Heat pump pool heaters <br /> minimum GOP= 4.0 <br /> Coolinglheating 403.6 Sizmg calculation performed & attached Minimt�m efficiencrss per <br /> 7ables 5032.3. Equipment efficiency verification required. Special <br /> equiprnent occasion cooling or heating capacify requires separate system or <br /> vanable capaciiy system. Efectric heat >10kW must be divided irlte two <br /> or more stages. <br /> �r, Ceilingstknee walis � 405.2.1 R-19 space permitting. <br /> t 1122/2613 1:28 PM EnergyGauge:�s�USA-FIa12es2014 Sect�on 405 4.1 CpmpEiant 5oftware Page fi ot G <br />