My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
14-14834
Zephyrhills
>
Building Department
>
Permits
>
2014
>
14-14834
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/12/2014 9:52:34 AM
Creation date
11/12/2014 9:48:23 AM
Metadata
Fields
Template:
Building Department
Company Name
ADVENTIST HEALTH SYSTEM
Building Department - Doc Type
Permit
Permit #
14-14834
Building Department - Name
ADVENTIST HEALTH SYSTEM
Address
7350 DAIRY RD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Installation <br /> All Model FDOT421 detectors use a surface-mounting Model FDOT421 fire detectors can be applied within <br /> base, Model DB-11 or Model DB-11 E, which mounts the maximum 30-feet center spacing(900 sq.ft. <br /> on a 4-inch octagonal, square or single gang areas,)as referenced in NFPA 72. This application <br /> electrical box. The base utilizes screw-clamp contacts guideline is based on ideal conditions,specifically, <br /> for electrical connections and self-wiping contacts for smooth ceiling surfaces, minimal air movement,and <br /> increased reliability. no physical obstructions between potential fire <br /> The Model DB-11 base can be used with the optional sources and the actual detector. Do not mount <br /> Model LK-11 detector locking kit,which contains 50 detectors in close proximity to ventilation or heating <br /> detector locks and an installation tool to prevent and air conditioning outlets. Exposed joints or <br /> unauthorized removal of the detector head. Model beamed ceilings may also affect safe spacing <br /> DB-11 has decorative plugs to cover the outer limitations for detectors. <br /> mounting screw holes. Should questions arise regarding detector placement, <br /> Model FDOT421 may be installed on the same observe NFPA 72 guidelines. Good fire-protection <br /> initiating circuit with the Siemens Model'H'-series system engineering and common sense dictate how <br /> detectors (Models HFP-11 and HFPT-11); Model and when fire detectors are installed and used. <br /> 'HMS'-series manual stations; Model'HTRI'-series Contactyour local Siemens Industry—Fire Safety <br /> interfaces; Model HCP output-control devices, or distributor or sales office whenever you need <br /> Model'HZM'-series of addressable, conventional assistance applying Model FDOT421 in unusual <br /> zone modules for FireFinder XLS control panels. applications. Be sure to follow NFPA guidelines and <br /> �UL Listed 1�ULC Pending installation instructions— <br /> All Model FDOT421 detectors are approved for included with every Siemens—Fire Safety detector— <br /> operation within the�UL-specified temperature and local codes as for all fire protection equipment. <br /> range of 32 to 100°F(0 to 38°C). <br /> Model DPU Technical Data <br /> The Device Program 1 Test Unit accessory is used to Operating <br /> program and verify the address of the detector. The Temperatures: +32°F (0°C) to 100°F (38°C) <br /> technician selects the accessory's program mode, Relative Humidity: 0-95°�; non-condensing <br /> and enters the desired address. Model DPU <br /> automatically sets and verifies the address and tests Air Velocity: 0-4,000 ft. 1 min (0-20m I sec) <br /> the detector. <br /> Model DPU operates on AC power or rechargeable Air Pressure: No effect <br /> batteries, providing flexibility and convenience in Maximum Spacing: 30-foot centers (900 sq. ft.), <br /> programmer and testing equipment from practically per NFPA 72 and�l.1LC-5524 <br /> any location. pending <br /> When in the test mode, Model DPU will perform a Input Voltage Range: 16VDC— 30VDC <br /> series of diagnostic tests without altering the <br /> address or other stored data,allowing technicians to Alarm Current: 410uA, max. <br /> determine if the detector is operating properly. <br /> Standby Current: 250uA, max. <br /> Application Data (average> <br /> Installation of the Model FDOT421 series of fire Detector Sensitivity Range: aUL: 1.10°�to 2.62%1 ft. <br /> detectors requires a two-wire circuit. In many retrofit �ULC: 1.44 to 3.06�01 ft. <br /> cases,existing wiring may be used. T-tapping'is Pending <br /> permitted only for Style 4(Class B)wiring. Model <br /> FDOT421 is polarity insensitive,which can greatly Thermal Rating: <br /> reduce installation and debugging time. • Fixed-temperature set point: 135°F(57°C) <br /> ■ Rate-of-Rise Detection: 15°F/min. (8.3°C/min) <br /> Detector Weight: 0.317 Ibs. (0.144 kg.) <br /> Mechanical Protection Guard: <br /> 4UL Listed I�ULC Pending <br /> with STI Guard Model STI-9604 <br /> SIEMENS Industry, Inc. <br /> Building Technologies Division <br />
The URL can be used to link to this page
Your browser does not support the video tag.