My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
14-14834
Zephyrhills
>
Building Department
>
Permits
>
2014
>
14-14834
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/12/2014 9:52:34 AM
Creation date
11/12/2014 9:48:23 AM
Metadata
Fields
Template:
Building Department
Company Name
ADVENTIST HEALTH SYSTEM
Building Department - Doc Type
Permit
Permit #
14-14834
Building Department - Name
ADVENTIST HEALTH SYSTEM
Address
7350 DAIRY RD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Specifications — (continued) <br /> Operation of each PAD-4 unit is controlled by Each unit is packaged in its own sheet-metal <br /> firmware stored in Flash memory on the main board, enclosure with sufficient space to house up to 7AH <br /> as well as the storage of a 10-event log,which can battery sets.The enclosure(Model PAD-4-ENCL) is <br /> be viewed via Model PAD-4-FDT. In the event that available in red. <br /> an upgrade to the system firmware is required,the The battery charger used in each unit can energize <br /> firmware can be transferred to the system without batteries of up to 18AH. Though,when battery sets <br /> the replacement of firmware chips. greater than 7AH are required,the battery set must <br /> An optional firmware-download software tool, be housed in a System 3 enclosure or a separate <br /> Model PAD-4-FDT,can be used for system diagnostic m�UL Listed battery enclosure. <br /> testing of the following: System 3 enclosures may also be used to house <br /> • Primary-powervoltage readouts multiple Model PAD-4 units in a single enclosure,via <br /> • Current draw for power charger <br /> • Configuration switch settings the Model S3AP Adapter Plate.Two(2)units are <br /> ■ Firmware version capable of sharing the same battery set when <br /> • Batteryvoltage mounted in the same enclosure. Model S3AP can <br /> When the tool is in communication with Model PAD- also be used to mount the PAD-4 main board and <br /> 4-MB,the'Test Mode'LED is illuminated. Model 170-Watt power supply(Model FP2011-U1)into a <br /> PAD-4-LUA is a USB serial port adapter that is PAD-3 enclosure. <br /> required for tool-kit operation. Each Model PAD-4-series unit complies with seismic <br /> Each NAC extender supervises a variety of functions certification, pursuant to ASC/SEi 7-05,Section <br /> including: 13.2.2,when used with the PAD-4 battery bracket <br /> • �ow Ac power (Model PAD4-BATT-BRKT). <br /> • Battery-voltage level <br /> • Earth ground-fault conditions <br /> All power can be directed to two(2)'Class A'or four Configuration Options <br /> (4)'Class B'power-limited NACs. Each NAC supports 0 � .� �� � <br /> up to 3 Amps per circuit. Either one(1)or two(2) � ����'� ' <br /> inputs can control four(4)outputs,which are � In �c i All outputs 'Class B•������ts <br /> compatible with all Siemens—Fire Safety 24VDC 2 Input 1 All outputs 'Class B•��r���u <br /> alarm signaling devices. In �t z• Silences horns on Output 1 — <br /> Input 1 Outputs 1 and 2 'Class B'circuits <br /> In cases where'Class A'circuits are used,an optional 3 In �t 2 Outputs 3 and 4 'Class B���r���cs <br /> Model PAD-4-CLSA module can be added, providing 4 Input 1 o�tP�t i 'Class B���r���ts <br /> two(2)additional'Class A'outputs to each PAD-4 I� �t z o�tPuu z,3 and 4 'Class B�c�rc��ts <br /> U Il It. 'Class A' <br /> 5 Input 1 Outputs 1 through 4 �ircuit pairs <br /> Each NAC extender is also capable of operating other <br /> parts of a Siemens fire alarm system,such as door Input 1 Outputs 1 through 4 "Class A• <br /> holders,via 3 Amps @ 24VDC max of power-limited 6 circuit pairs <br /> auxiliary output. When the output activated,the In �t z• Silences horns on Outputl <br /> Input 1 Outputs 1 and 2 "Class A' <br /> total power available cannot exceed 6 Amps when � circuit pairs <br /> used with Models FP2011-U1 or 9 Amps when used 'Class A• <br /> wlth FP2012-U1. Input 2 Outputs 3 and 4 p rs <br /> circuit ai <br /> Trouble conditions are monitored through each Input 1 Outputs 1 and 2 �Class A• <br /> 8 circuit pairs <br /> unit's two(2) inputs. In addition,one(1)'Form C' Ir, �cz Outputs3 and4 'ClassB���r���u <br /> Trouble contact is provided for monitoring each unit *denotes when used with Siemens Model:45;'NS'or7H'-series <br /> that is connected through the input of a Siemens horn/strobedevices <br /> FACP. Therefore,the user has the option of <br /> connecting a PAD-4 NAC extender unit into a NAC of <br /> a Siemens FACP,or the unit may be monitored with <br /> a Model TRI-series monitoring module on a Siemens <br /> intelligent fire system. <br /> A separate'Form C'Trouble contact is used <br /> exclusively with each NAC extender to indicate AC <br /> Fail Trouble events on the NAC extender. <br /> SIEMENS Industry, Inc. <br /> Building Technologies Division <br />
The URL can be used to link to this page
Your browser does not support the video tag.