My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
14-14834
Zephyrhills
>
Building Department
>
Permits
>
2014
>
14-14834
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/12/2014 9:52:34 AM
Creation date
11/12/2014 9:48:23 AM
Metadata
Fields
Template:
Building Department
Company Name
ADVENTIST HEALTH SYSTEM
Building Department - Doc Type
Permit
Permit #
14-14834
Building Department - Name
ADVENTIST HEALTH SYSTEM
Address
7350 DAIRY RD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Technical Data <br /> �UL tisted Maders and Ratings <br /> �����VO�� Maximum RMS Current dBA at 1 D Feet <br /> E�����`�����d�} (Chime Only) Reverberant <br /> Mo�is �Per�UL 4641 <br /> (1/DCNRMS} Max Min Max <br /> CH' 16-33.0 Q.022 52 58 <br /> CH-CW 16-33_U U.022 52 58 <br /> •Available in red and white <br /> Note: These notification appliances are OUL Listed as"Special Application,°and are intended to be used <br /> only with Siemens notification-appliance circuits. <br /> NOTES: <br /> 1.The chime must be set at maximum volume for Private Mode Fire Protective Service per f►11.11464 listing requirements. <br /> 2.The chime produces a brief inrush current of 0.100 Amps with filtered DC input[0.140 Amps with full-wave-rectified <br /> (VRMS)input]with a duration of 100 milliseconds. <br /> �t!L tiated Maiets e�d Ratirrgs <br /> (� �PP��+�1 �irKm Rt� �A at 1Q Fxt <br /> Modd [Per�UL 1971] ������ R�� (Well Mot+�t) <br /> �v��sr r� tia► � <br /> CH-M�C' 16.0-33.0 O.d24 52 58 1513N75J110 <br /> •Available in red and white <br /> NOTES: <br /> 1.The strobe will produce 1 flash per second over the Input Voltage range. <br /> 2.The strobes meet the required light distribution patterns defined in�UL 1971. <br /> 3.The chime must be set at maximum volume for Private Mode Fire Protective Service per QUL 464 listing requirements. <br /> 4.The chime produces a brief inrush current of 0.100 Amps with filtered DC input[0.140 Amps with full-wave-rectified <br /> (VRMS)input]with a duration of 100 milliseconds. <br /> f :`WARNING:CANDELA SETTING WILL DETERMINE THE CURRENT DRAW OF THE PRODUCT <br /> b�UL Suobe Gurt�tr Rar�ngs Only <br /> Maximum RMS Current CM�pa) <br /> V 15cd 30cd 75cd 140Cd <br /> DG 1 fi-33VDC 0.064 0_09B Q_175 0_233 <br /> FWR 16-33VRMS 0.1Q8 Q.164 0258 0_388 <br /> Details for Ordering — (Including Mounting Options & Agency Approvals) <br /> Agency Approvals <br /> „� . � A "v *'�i � a k <br /> �F #.'i�t r�. � �� u�:� {.� <br /> CH-MC-R 500-636017 Chime:Multi Candela,Red P,Q,R,U,Y X X X X <br /> CH-MC-W 500-636018 Chime:Multi Candela,White P,Q,R,U,Y X X X X <br /> CH-MC-CR 500-636021 Chime:Multi Candela,Ceilin /Red ,U X X X X <br /> CH-MC-CW 500-636022 Chime:Multi Candela,Ceilin /White Q,U X X X X <br /> CH-HMC-CW 500-636023 Chime:Hi Multi Candela,Ceilin /White Q,U X X X X <br /> CH-R 500-636019 Chime:Red P,Q,R,U,Y X X X X <br /> CH-W 500-636020 Chime:White P,Q,R,U,Y X X X X <br /> CH-CW 500-636024 Chime:Ceilin /White Q,U X X X X <br /> X =listed I approved *=Refer to catalog sheet#:2585 for detailed mounting options <br /> Notice: This marketing catalog sheet is not intended to be used for system design or installation purposes. <br /> For the most up-to-date information, refer to each producYs installation instructions. <br /> Fire Safety Fire Safety <br /> 8 Femwood Road 2 Kenview Boulevard <br /> SIEMENS Industry, If1C. Florham Park,NJ 07932 Brampton,Ontario ��S� <br /> Building Technologies Division Tel:(973)593-2600 (Sn) L6T 5E4/Canada Supersedes sheet dated 7/07 <br /> FAX:(908)547-6877 Printed in U.S.A. Tel:(905)799-9937 (Rev.1� <br /> URL:www.SBT.Siemens.com/FIS FAX:(905)799-9858 <br />
The URL can be used to link to this page
Your browser does not support the video tag.