My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
14-14948
Zephyrhills
>
Building Department
>
Permits
>
2014
>
14-14948
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/12/2014 9:55:28 AM
Creation date
11/12/2014 9:53:33 AM
Metadata
Fields
Template:
Building Department
Company Name
LOAN FUNDINGS SOLUTIONS II LLC
Building Department - Doc Type
Permit
Permit #
14-14948
Building Department - Name
LOAN FUNDING SOLUTIONS II LLC
Address
38130 PRETTY POND RD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
December 12, 2013 Sprinkler4la <br /> � MICROFAST°AND <br /> � . � . � MicrofastHP°QUICK <br /> RESPONSE PENDENT <br /> SPRINKLERS <br /> The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 <br /> Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com <br /> 1. DESCRIPTION <br /> Viking Microfast� and MicrofastHP� Quick Response Pendent Sprinklers are small, <br /> thermosensitive, glass-bulb spray sprinklers available in several different finishes <br /> and temperature ratings and K-Factors to meet design requirements. The special <br /> Polyester,Polytetrafluoroethylene (PTFE), and Electroless Nickel PTFE (ENT) <br /> coatings can be used in decorative applications where colors are desired. In ad- <br /> dition, these coatings have been investigated for installation in corrosive atmos- ' ��� <br /> pheres and are listed/approved as corrosion resistant as indicated in the Approval <br /> Charts. (Note: FM Global approves ENT finish as corrosion resistant. FM Global �� <br /> has no approval classification for PTFE and Polyester coatings as corrosion resist- ' �4: <br /> ant.) <br /> i ` <br /> 2. LISTINGS AND APPROVALS °; �� <br /> ;��• <br /> �O�S cULus Listed: Category VNIV <br /> 0 FM Approved: Classes 2001, 2002, 2015, and 2017 <br /> "'"` NYC Approved:Calendar Number 219-76-SA and MEA 89-92-E,Volume 16 PN 12979 PN 066666 <br /> ABS Certified: Certificate 04-HS407984C-PDA <br /> �as VdS Approved: Certificates G4040095, G4040097, G4060056, G4060057, G4880045, G4930�J38, and G4980021 <br /> �, LPC Approved: Ref. Nos. 096e/03 and 096e/04 <br /> �E CE Certified: Standard EN 12259-1, EC-certificates of conformity 0786-CPD-40130,0786-CPD-40170 and 0786-CPD- <br /> 40279, 0832-CPD-2001, and 0832-CPD-2003 <br /> MED Certified: Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008 <br /> NOTE: Other International approval certificates are available upon request. <br /> Refer to Approval Chart 1 and Design Criteria on page 41d for cULus Listing requirements anci refer to Approval Chart 2 <br /> and Design Criteria on page 41f for FM Approval requirements that must be followed. <br /> 3. TECHNICAL DATA <br /> Specifications: <br /> Available since 1987. <br /> Minimum Operating Pressure: 7 psi (0.5 bar)' — <br /> Maximum Working Pressure: Sprinklers 12282 and 12290 are rated for viking Technical Data may be found on <br /> use with water working pressures ranging from the minimum 7 psi The viking Corporation's web site at <br /> (0.5 barj up to 250 psi(17 bar)for high-pressure systems. High-pres- http://www.vikinggroupinc.com. <br /> sure (HP)sprinklers can be identified by locating "250" stamped on The web site may include a more recent <br /> the deflector.All other Part Nos. not mentioned above are rated to a edition of this Tschnical Data Page. <br /> maximum 175 psi (12 bar)wwp. <br /> Factory tested hydrostatically to 500 psi (34.5 bar) <br /> Thread size: Refer to the Approval Charts <br /> Nominal K-Factor: Refer to the Approval Charts <br /> Glass-bulb fluid temperature rated to-65 °F(-55 °C) <br /> Overall Length: Refer to the Approval Charts <br /> `cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operatinq pressure for LPCB and CE <br /> Approvals ONLY is 5 psi(0.35 bar). <br /> Material Standards: <br /> Frame Casting: Brass UNS-C84400 or QM Brass for Sprinklers 12979 and 12282. Brass UNS-C84400 for all other sprinklers. <br /> Deflector: Phosphor Bronze UNS-051000 or Copper UNS-C19500 for Sprinklers 12979, 066666, and 06765B. Copper UNS- <br /> C19500 for Sprinkler 12282. Phosphor Bronze UNS-051000,Copper UNS-C19500 or Brass UNS-C2Ei000 for Sprinkler 067206. <br /> Brass UNS-C26000 for all other Sprinklers. <br /> Bushing (for Sprinklers 06718B, 06720B, and 12290): Brass UNS-C36000 <br /> Bulb: Glass, nominal 3 mm diameter <br /> Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape <br /> Screw: Brass UNS-C36000 <br /> Pip Cap and InsertAssembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 <br /> For PTFE Coated Sprinklerc Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-PTFE Coated <br /> �r Polyester Coated Sorinkl r Belleville Spring-Exposed <br /> For ENT Coated Sprinklers Belleville Spring-Exposed, Screw and Pipcap-ENT coated. <br /> Form No. F_081296 Replaces page 41 a-f, dated December 4, 2013. <br /> (Added E-3 Escutcheon) <br />
The URL can be used to link to this page
Your browser does not support the video tag.