Laserfiche WebLink
2.2 Test requirements <br /> 72.0" x 6�.0" PVC Horizontal Slicling Windo�v <br /> 2.2.3 Structural Performance Test <br /> 2.2.3.1 Eatecior Pressure (ASTM E330-O2) <br /> Range Time(seconds) Load (psfl <br /> Half Proof Positive 10 12.5 <br /> Proof Positive l0 25.0 <br /> 2.2.3.2 Interior Pressure (ASTM E330-02) <br /> Range Time(seconds) Load (ps� <br /> Half Proof Negative 10 6.25 <br /> Proof Negative 10 12.5 <br /> 2.2.4 Air Infltration Test (ASTM E283-04) <br /> Pressure SCFM/Ft^2 Result <br /> 1.57 PSF 0.008 Pass <br /> 2Z.5 Water Resistance Test (ASTM E�47-OU) <br /> Pressure Time Result <br /> 0.00 PSF (4) -5 Min. Cycle Pass (with screen) <br /> 0.00 PSF (4) -5 Min. Cycle Pass (without screen) <br /> Note:At tlre completion of n!!Ioa�Lr E_rlerior un�!Li�erior Nrere were�ro co�rdilinns thm ren�lere�l the <br /> specimen inoperable. <br /> PF 429 TEL!4 02020439 P8{�E Z OPJ <br />