Laserfiche WebLink
Miscellaneous Report � <br /> Winter: 40 37.52 80% n/a 70 n/a <br /> Summer: 91 77 54% 50% 75 52.95 <br /> Main Trunk Runouts <br /> Calculate: Yes Yes <br /> Use Schedule: Yes Yes <br /> Roughness Factor: 0.00300 0.01000 <br /> Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./100 ft. <br /> Minimum Velocity: 650 ft./min 450 ft./min <br /> Maximum Velocity: 900 ft./min 750 ft./min <br /> Minimum Height: 0 in. 0 in. <br /> Maximum Height: 0 in. 0 in. <br /> Winter Summer <br /> Infiltration Specified: AC/hr(rm AC/hr(rm <br /> 0.236 specified) 0.236 specified) <br /> 50 CFM 50 CFM <br /> Infiltration Actual: 0.236 AC/hr(rm 0.236 AC/hr(rm <br /> specified) specified) <br /> Above Grade Volume: X 12.694 Cu.ft. X 12.694 Cu.ft. <br /> 3,000 Cu.ft./hr 3,000 Cu.ft./hr <br /> X 0•0167 X 0•0167 <br /> Total Building Infiltration: 50 CFM 50 CFM <br /> Total Building Ventilation: 50 CFM 50 CFM <br /> ---System 1--- <br /> Infiltration&Ventilation Sensible Gain Multiplier: 17.59 = (1.10 X 0.999 X 16.00 Summer Temp. Difference) <br /> Infiltration&Ventilation Latent Gain Muttiplier: 35.98 = (0.68 X 0.999 X 52.95 Grains Difference) <br /> Infiltration&Ventilation Sensible Loss Multiplier: 32.98 = (1.10 X 0.999 X 30.00 Winter Temp. Difference) <br /> Winter Infiltration Specified: 0.236 AC/hr(rm specified)(50 CFM) <br /> Summer Infiltration Specified: 0.236 AC/hr(rm specified)(50 CFM) <br /> C:\Users\Jaosn\Documents\Elite Software\Rhvac 9 Projects\PIPER,H.rh9 Thursday, February 27,2014, 11:46 AM <br />