Laserfiche WebLink
10) Silencers Ives Rockwood, Hager <br /> 11) Key Cabinet Lund Key Control <br /> C. If material manufactured by other than that specified or listed herewith as an equal, is to be bid <br /> upon, permission must be requested from the architect seven (7)days prior to bidding. If <br /> substitution is allowed, it will be so noted by addendum. <br /> 2.2 FINISH OF HARDWARE: <br /> A. Exterior Hinges to be Stainless Steel (32D)and Interior hinges to be Satin Chrome(26D) Door <br /> Closers to be Aluminum, Locks to be Satin Chrome(26D). Exit Devices to be Satin Chrome <br /> (26D). Overhead Holders to be Satin Chrome(26D), Stainless Steel (32D) and the Thresholds to <br /> be Mill Finish Aluminum. <br /> 2.3 HINGES AND PIVOTS: <br /> A. Exterior butts shall be Stainless Steel. Butts on all out swinging doors shall be furnished with <br /> non-removable pins(NRP). <br /> B. Interior butts shall be as listed. <br /> C. Doors 5'or less in height shall have two(2) butts. Furnish one(1)additional butt for each 2'6" in <br /> height or fraction thereof. Dutch door shall have finro(2) butts per leaf. <br /> 2.4 KEYING: <br /> A. Locks and cylinders shall be Schlage Lock Company.All bittings shall be issued by lock <br /> manufacturer in order to create a grand master key system. <br /> B. Locks and cylinders to be construction master keyed in a manner that does not require the <br /> cylinders to be removed. <br /> C. Provide Two(2) each change keys per lock and Six (6)each construction master keys. <br /> 2.5 LOCKSETS: <br /> A. Locksets shall be Heavy Duty Cylindrical type, unless specified otherwise, in"ND" and "AL" <br /> series, lever design as manufactured by Schlage Lock. <br /> 1. Acceptable substitutions: NONE(Owners standard <br /> 2.6 EXIT DEVICES: <br /> A. All devices shall be Von Duprin 98 Series in types and functions specified. All devices must be <br /> listed under"Panic Hardware" in accident equipment list of Underwriters Laboratories. All labeled <br /> doors with"Fire Exit Hardware"must have labels attached and be in strict accordance with <br /> Underwriters Laboratories. <br /> B. All exit devices shall be tested to ANSI/BHMA A156.3 test requirements by a BHMA certified <br /> testing laboratory. <br /> C. All surface strikes shall be roller type and come complete with a plate underneath to prevent <br /> movement.And shall be provided with a dead-latching feature to prevent latchbolt tampering. <br /> 1. Acceptable Substitutions: NONE(Owners standard <br /> 2.7 DOOR CLOSERS: <br /> A. All closers shall be LCN 4000 and 1461 series with slim cover having non-ferrous covers, steel <br /> arms separate valves for adjusting backcheck, closing and latching cycles and adjustable spring <br /> @2014,HJ/12010.00 FINISH HARDWARE-REVISED PER ADDENDUM 1 08 71 00-3 <br />