My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
14-15210
Zephyrhills
>
Building Department
>
Permits
>
2014
>
14-15210
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/30/2015 11:57:57 AM
Creation date
3/30/2015 11:57:56 AM
Metadata
Fields
Template:
Building Department
Company Name
MAJESTIC OAKS
Building Department - Doc Type
Permit
Permit #
14-15210
Building Department - Name
NHC-FL 115 LLC (JACK MULLINS)
Address
3807 PRARIE DUNES ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�•��l�°i�'i�r�t�!�1►��I� � ,. ��I�!�� <br /> � s ���� ' � :. ��� <br /> Proiect Report <br /> Project Title: Mullins Residence <br /> Designed By: Blake Lanier <br /> Project Date: Tuesday,April 22,2014 <br /> Client Name: Mullins Kondrotas <br /> Client Address: 3807 Prarie Dunes St <br /> Client City: Zephyrhills, FI 33542 <br /> Client Phone: 765-748-5194 <br /> Company Name: And Services <br /> Company Representative: Blake Lanier <br /> Company Address: 6008 Jet Port Industrial Blvd <br /> Company Ciry: Tampa, FI 33770 <br /> Company Phone: 813-445-4818 <br /> Company Fax: 813-881-1400 <br /> Reference City: Tampa AP, Florida <br /> Building Orientation: Front door faces West <br /> Daily Temperature Range: Medium <br /> Latitude: 28 Degrees <br /> Elevation: 19 ft. <br /> Altitude Factor: 0.999 <br /> Outdoor Outdoor Outdoor Indoor Indoor Grains <br /> �Bulb Y.1Let.�ulh BsLtiUnl S�LHi1u1 Drv Bulb Difference <br /> Winter: 40 37.52 n/a n/a 70 n/a <br /> Summer: 91 77 54% 50% 75 53 <br /> Total Building Supply CFM: 1,085 CFM Per Square ft.: 1.205 <br /> Square ft. of Room Area: 900 Square ft. Per Ton: 365 <br /> Volume(ft3)of Cond. Space: 10,800 <br /> Total Heating Required Including Ventilation Air: 17,409 Btuh 17.409 MBH <br /> Total Sensible Gain: 24,900 Btuh 84 % <br /> Total Latent Gain: 4,718 Btuh 16 % <br /> Total Cooling Required Including Ventilation Air: 29,618 Btuh 2.47 Tons(Based On Sensible+ Latent) <br /> Rhvac is an ACCA approved Manual J and Manual D computer program. <br /> Calculations are performed per ACCA Manual J 8th Edition,Version 2, and ACCA Manual D. <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at <br /> your design conditions. <br /> C:\Users\Jaosn\Documents\Elite Software\Rhvac 9 Projects\PIPER,H.rh9 Tuesday,April 22,2014, 3:48 PM <br />
The URL can be used to link to this page
Your browser does not support the video tag.