My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
14-15239
Zephyrhills
>
Building Department
>
Permits
>
2014
>
14-15239
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/3/2015 2:07:32 PM
Creation date
4/3/2015 2:04:32 PM
Metadata
Fields
Template:
Building Department
Company Name
ZEPHYR COMMONS
Building Department - Doc Type
Permit
Permit #
14-15239
Building Department - Name
MATTRESS FIRM
Address
7880 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�)II✓�� � <br /> a � . <br /> � - <br /> i� � =-_t � -- ' . .�, <br /> ` i �� � <br /> ` _. , : . <br /> ♦ : ,i ' a, � . <br /> � ♦ ,. <br /> J�_ \ . _. _. t ��`__ , <br /> 1 <br /> ° • � � BB9 �- easyseals.com <br /> �'�r�s�' <br /> DE�IGiV C/�L�IJL�TIONS <br /> FOR <br /> �Gi���E55 FIRf� <br /> � �id� E�evation � <br /> Wi��L-�VIOUN��D �IGNS <br /> US Wena�301�c Kossi@�Rd—Zephyrhills <br /> GENERAL NOTES: <br /> 1. Design is in accordance with the 2010 Florida Building Code for use within <br /> and outside the High Velocity Hurricane Zone(HVHZ). <br /> 2. Wind loads have been calculated per the requirements of ASCE 7-10 as <br /> shown herein. <br /> 3. These engineering calculations pertain only to the structural integrity of <br /> those systems, components,and/or other construction explicitly specified <br /> herein and/or in accompanying engineering drawings. The existing host Index: <br /> structure(if any)must be capable of supporting the loaded system as pg 1 Cover <br /> verified by building department or architect/engineer of record. No pg 2 Wind Loads <br /> warranty,either expressed or implied,is contained herein. <br /> Pg 3 Anchor Design <br /> 4. System components shall be as noted herein. All references to named <br /> components and installation shall conform to manufacturer's or industry <br /> specifications as summarized herein. <br /> 5. Where site conditions deviate from those noted herein,revisions may be , <br /> required or a separate site-specific engineering evaluation performed. Engineer s signature and seal valid <br /> forpages 1 through 3 <br /> 6. Aluminum components in contact with steel or embedded in concrete shall � _ � <br /> be protected as prescribed in the 2005 Aluminum Design Manual,Part 1A. <br /> Steel components in contact with, but not encased in,concrete shall be - <br /> coated, painted,or otherwise protected against corrosion. -- <br /> 7. Engineer seal affixed hereto validates structural design as shown only. Use �2 14 <br /> of this specification by contractor,et.AI,indemnifies and saves harmless <br /> this engineer for all costs&damages including legal fees&apellate fees Christian Langley - - E#67382 <br /> resulting from deviation from this design. Easy Se81S Cert th#29531 <br /> 1200 N Federal Hwy,#200 C I�. <br /> Boca Raton,FL 33432 ����-7eQl�.COIII Page 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.