I�hvac-Residential 8�Light Commercial HVAC Loads Elite Software Development,Inc.
<br /> And Services [Sarasota] � � Beson Residence
<br /> Sarasota FL 34234 � Pa e 6
<br /> TotalBuildin Summar Loads
<br /> Component � Area Sen Lat Sen Total
<br /> Descri tion � Quan Loss Gain Gain Gain
<br /> 1A-hm-o: Glazing-Single pane, operable window, heat- 192 7,316 0 13,496 13,496
<br /> absorbing, metal frame no break, u-value 1.27,
<br /> SHGC 0.52
<br /> 12A-3sw:Wall-Frame, no insulation in stud cavity, R-3 552 2,599 0 2,175 2,175
<br /> board insulation, siding finish,wood studs
<br /> 16A-11: Roof/Ceiling-Under Attic with Insulation on Attic 1225.8 2,979 0 7,049 7,049
<br /> Floor(also use for Knee Walls and Partition
<br /> Ceilings), Unvented Attic, No Radiant Barrier,Any
<br /> Roofing Material,Any Roof Color, R-11 insulation
<br /> 20P-19-c: Floor-Over open crawl space or garage, 1225.8 1,839 0 674 674
<br /> Passive, R-19 blanket insulation, carpet covering
<br /> Subtotals for structure: 14,733 0 23,394 23,394
<br /> People: 2 400 460 860
<br /> Equipment: 0 0 0
<br /> Lighting: 40 136 136
<br /> Ductwork: 0 0 0 0
<br /> Infiltration:Winter CFM: 40, Summer CFM:40 1,319 1,439 704 2,143
<br /> Ventilation:Winter CFM:40, Summer CFM:40 1,319 1,439 704 2,143
<br /> AED Excursion: 0 0 783 783
<br /> Total Building Load Totals: 17,371 3,278 26,181 29,459
<br /> Check Fi ures
<br /> Total Building Supply CFM: 1,159 CFM Per Square ft.: 0.945
<br /> Square ft. of Room Area: 1,226 Square ft. Per Ton: 499
<br /> Volume(f�)of Cond. Space: 14,709
<br /> Buildin Loads
<br /> Total Heating Required Including Ventilation Air: 17,371 Btuh 17.371 MBH
<br /> Total Sensible Gain: 26,181 Btuh 89 %
<br /> Total Latent Gain: 3,278 Btuh 11 %
<br /> Total Cooling Required Including Ventilation Air: 29,459 Btuh 2.45 Tons(Based On Sensible+ Latent)
<br /> Notes
<br /> Rhvac is an ACCA approved Manual J and Manual D computer program.
<br /> Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
<br /> All computed results are estimates as building use and weather may vary.
<br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
<br /> your design conditions.
<br /> C:\Users\Jaosn\Documents\Elite Software\Rhvac 9 Projects\PIPER,H.rh9 Monday, May 12, 2014, 12:45 PM
<br />
|