Laserfiche WebLink
,, . �_ <br /> 5 <br /> R W R W Building Consultants, Inc. <br /> B Consulting and Engineering Services for the f3uilding Industry <br /> C P.O.[�ax 230 Valrico,FL 33595 Phanc 813.G59.9197 <br /> Florida Board of Professional Engineers Certificale of Authorizntion No.9813 <br /> i � � � ��� ; <br /> � / <br /> Product <br /> Category Sub Category Manufacturer Product Name <br /> - NewSouth�ndow Solutions Vantage <br /> W(ndows Double Hung 4901 Oak Fair Blvd Double Hung Window _ <br /> Tampa,FL 33610 "Non-ImpacY' <br /> 513 284.0129 <br /> Scope: Product Evaluation report issued by R W Building Consultants, Inc.&Lyndon F.Schmidt, P.E.(System ID#1998)for <br /> NewSouth Window Solutions,based on Rule Chapter No.9N-3,Method 1A of the State of Florida Product Approval,Dept. <br /> of Business&P[ofessional Regulation. <br /> � RW Building Consultants and Lyndon F.Schmidt,P.E.do not have nor will acquire financial interest in the company ' <br /> manufacturing or distributing the product or in any other entitq involved in the approval process of the product named <br /> herein. <br /> Limitations: <br /> 1. This product has been evaluated and is in compliance with the 2010 Florida Building Code(FBC)structural requirements excluding the <br /> "High Velocity Hurricane Zone"(HVHZ).See the Certification Agency Certificate for sizes,specifications and ratings. <br /> 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing <br /> or stucco. <br /> 3. When used in areas requiring wind bome debris protection,this product is required to be protected with an impact resistant covering <br /> that complies with Section 1609.1.2 of the Florida Building Code. <br /> 4. For 2x stud framing construction, anchoring of these units shall be the same as that shown for 2x buck masonry construction. <br /> 5. Site conditions that deviate from the details of drawing FL-15378.7 require further engineering analysis by a licensed engineer or <br /> registered architect. <br /> 6. See drawing FL-15378.7 for size and design pressure limitations. <br /> Supporting Documents: <br /> 1. Test Reaort No. Test Standard - Testinq Laboretorv Siqned bv <br /> ATI A5889.03-501-44 AAMA/WDMA/CSA 101/I.S.2/A440-08 Architectural Testing, Inc. Lynn George <br /> 2. Drawinq No. Prepared bv Siqned&Sealed bv <br /> No.FL-15378.7 RW Building Consultants,Inc.(CA#9813) Lyndon F.Schmidt, P.E. <br /> 3. Calculations Prepared bv SiQned 8 Sealed bv <br /> Anchoring RW Building Consultants,Inc.(CA#9813) Lyndon F.Schmidt,P.E. <br /> 4. Qualitv Assurance <br /> Certificate of Participation issued by Keystone Certifications,Inc.,certifying that NewSouth Window Solutions is <br /> manufacturing products within a quality assurance program that complies with ISO/IEC 17020 and Guide 53. <br /> � ��-��= <br /> Lyndon F.Schmidt,P.E. <br /> FL PE No.43409 <br /> PF 1651 3/28/2012 <br /> Sheet 1 of 1 <br />