Laserfiche WebLink
PROFILE A <br /> TYPICAL CATV DIREC110NAL BORE CROSSING ROAD ROW STANDARD TRENCH DETAIL <br /> 10TH STREEf LOOKING NORTHWEST <br /> Row gp' Row <br /> EXISi1NG GRADE EXISiING GRADE <br /> NOTE: <br /> 18� Eop 1z� �I� 72� ' Eop 18' iRENCH SHALL BE BACK FlLLED IN <br /> • ° � UFTS NOT TO EXCEED 12'. AND COMPACTION <br /> I I � � � 38�� MIN. DETERMIN DuBY AAS O�T-180 AS <br /> � i IB�� j� � gmde �� � � � 36" MIN. 12� <br /> � ' 3a I 24 ��$ Q � 5•� •Ln 5o PROPOSED CABLE�FIDPE/SCHEDULE 40 CONDUIT <br /> -----�------------------ ------------- --------- --- --- <br /> -------------�----- " o � <br /> � 22' 22' � z�0,�° QQ . o Q ° <br /> : 10' � 10---- -------� 30" Z a c¢icai ~ ~ � x <br /> ----- ------------- ------- ---- --- O <br /> - <br /> �------- - -------- - �----- - <br /> I ------- verizonpp i I �� �� ? � � w 2� <br /> -----�- -------------�-------- ---- --- ----- --------�----- 36" <br /> • __ _____________�_ � 42p LOWER QUADRANT TO BE SHAPED <br /> -----r--------------- , --------- wtr ----wtr-----------1----- HAND PLACED TO RECEIVE CAN CABLES AND <br /> iI � ��u p7p�p� TO RECEIVE HOPE /SCHEO. 40 CONDUIT <br /> -----�------------=----- ------------- ------------- ------------------�----- 60" <br /> i 1 � i <br /> I <br /> -----�------------------ -------------i------------- -------------------j----- �z^ <br /> I I I <br /> Proposed 44ft Directlonal Bore TYPICAL CAN RISER DETAIL <br /> Inetall (1) 2" Schedule 40 Conduit <br /> Directional Bore Roadway Mi�imum 36° Depth <br /> utility pole primary power linea <br /> secon ary power lines <br /> secondar ower lines <br /> other utility Iines 4p" min. <br /> 12" min. catv Itnes <br /> down guy 2° schedule 40 u-guard <br /> /steel riser u-guard <br /> 18' min. <br /> r <br /> NOiE: ALL EXISTING UTIUTY DEPTHS & LOCATIONS BASED ON A grade <br /> STANDARD, AVAILABLE RECORDS AND FIELD OBSERVATiONS. � <br /> WILL REQUIRE UNDERGROUND LOCATES PRIOR TO CONSTRUCiION. i <br /> A MINIMUM OF 24" VERTICAL AND 24" HORfZONTAL SEPARATION 36" mfn. ; <br /> FROM EXISTING UTILIIIES MUST BE OBSERVED. I � <br /> • A MINIMUM Of 18� VERTICAL AND 36° HORIZONTAL SEPARATION """'--"----"""°-"""""'`'--"'-""' <br /> FROM EXISTING GAS MAINS MUST BE OBSERVED. <br /> a...r.w r.�. APPLICATION FOR CITY PERMIT TO: PROJECT NAME:5311 lOTH STREET COUNTY:PASCO <br /> � b r i g h t � � � PLACE NEW 2"CONDUIT&CABLES WITHIN ROAD RIGHT OF WAY DATE:04-26-13 SECTION:11 TOWNSHIP:26 RANGE:21 <br /> � BRIGHTHOUSE ENGINEER:EDDIE THOMAS DRp�gy:M.B. <br /> 1 1 O U S G \ � JOH DESCRIPTION:INSTALLATION OF CARL NUMBER :224112 WORK ORDER#: SCALE:NONE <br /> NETNORKS ` ���_4� NEW CATV CONDUIT&CABLES TYPE OF-PERMIT:CITY 'fRACKING#:KNl 1-0761 DRAWING SHEET :3 OF 3 <br />