My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
14-15307
Zephyrhills
>
Building Department
>
Permits
>
2014
>
14-15307
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/23/2015 10:59:12 AM
Creation date
6/23/2015 10:59:08 AM
Metadata
Fields
Template:
Building Department
Company Name
WALNUT GROVE TOWNHOMES
Building Department - Doc Type
Permit
Permit #
14-15307
Building Department - Name
BUTTERFIELD MOBILE HOME
Address
37856 PRAIRIE ROSE LP LOT 2
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
68
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FOf?M 405-1'0 <br /> Fl;orida Code Compliance Checklist - <br /> , Florida Deparfinent of Business and Professional Regulations <br /> Residential Whole Building Pe►formance Method <br /> ADDRESS: 4408 Court Street PERMIT#: <br /> Zephyrhflls,FL,33542- <br /> � <br /> MANDATORY REQt11REMENTS SUMMARY-3ee individual code sections for full detaits. <br /> I COMPONENT SECTION SIJMMARYOF REQUlREMENT(S) CHECK Y <br /> Airleakage 402.4 To be caulked,gasketed, weatherstripped orotherwise sealed. <br /> Recessed lighting/Grated as meeting ASTM E 283. �ndows and <br /> doors=0.30 cfm/sq.ft. Testing or visua!inspection required. .�/ <br /> Firep/aces:gasketed doors&outdoor combusfion air. Musf complete , <br /> envelope leakage report or visually verify Table 402.4.2. � <br /> Thennostat& 403.9 At/east one theimostat shal!be provided for each separate heating <br /> controls and cooling system. Where forced-air fumace rs.primary sysfem, �✓ <br /> programmable thermostat is required.Heat�pumps with supplementa! <br /> e/ecfric heat must prevent supplemental heat when compressor can <br /> meet the/oad. • <br /> Ducts 403.2.2 A/l ducts, air handlers, �Iter boxes and bullding cavifies which form fhe � <br /> primary air containment passageways for air disfrrbufion systems sha!! <br /> be considered ducts or plenum chambers, shall be constructed and f <br /> sea/ed in accardance with Section 503.2.7.2 of this code. <br /> 403.3.3 Building framing cavitigs shall not be,used as supp/y ducts. <br /> � <br /> water heaters 403.4 Heat trap nequired for vertica/pipe risers. Comply with e�ciencies in <br /> Tab/e 403.4.3.2.Provide switch or clearfy marked circuit breaker <br /> {electric)or shutoff(gas). Clrculating sysfem pipes insu/ated to= <br /> "' R-2+accessible manual OFF switch. <br /> Mechanica! 403.5 Homes designed to operate at positive pressure or with mechanical <br /> ventilation ventifation systems shal!nof exceed the minimum ASHRAE 62 leveL � <br /> . No make-up air from attics, crawlspaces,garages or oufdoors adjacent ,/ <br /> . to poo/s or spas. , , � . <br /> SwimmingPools 403.9 'Poo/pumps and poo!pump motors wifh a total horsepower(HP)�f=1 <br /> &Spas _ . . HF shall have the capability of operafing af two or more speeds. Spas <br /> ,.; �-.• ' ,and�heated pools must have vapor-refardant covers or a liquid cover or� <br /> �� � • - � other means proven to reduce heat loss except rf 70%6 of hest from <br /> . sife-recovered energy. Off/timer switch required. Gas heaters mintmum �?E� <br /> therma/e�ciency=78%(82%affer 4/16/13). Heat pump pool heaters , <br /> � minimum COP=4.0. ` <br /> Cooling/heaSng � 403.6 Sizing calculatlon psrformed&aftached.Mlnimum effrciencies per <br /> 'Tables 503.2.3.Equipment e�ciency verification required. Specia! <br /> 'equipment oc�asion cooling orheating capacity requires separ,ate sysiem or `. : � <br /> variab/e capacity system. Electric heat>10kW must be divided into fwo <br /> , ormore steges. � <br /> Cerlings/kneewaNs 405.2.1 R-19 space pelmitting. � , <br /> 5i8/2014 i 1:07 AM EneryyGauye�USA-FlaRes2010 Sectlon 405.4.J Compfianf SoHwaro Page 5 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.