My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
14-15307
Zephyrhills
>
Building Department
>
Permits
>
2014
>
14-15307
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/23/2015 10:59:12 AM
Creation date
6/23/2015 10:59:08 AM
Metadata
Fields
Template:
Building Department
Company Name
WALNUT GROVE TOWNHOMES
Building Department - Doc Type
Permit
Permit #
14-15307
Building Department - Name
BUTTERFIELD MOBILE HOME
Address
37856 PRAIRIE ROSE LP LOT 2
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
68
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
P.�hvac-Re'sidential&Light Commercial HVAC Loads Eiite Software Development,Inc. <br /> HVAC Designs � Walnut Grove TH 1129 S <br /> Tam a FL 33615 ' Pa e i <br /> Pro'ect Re ort <br /> General Pro'ect Information <br /> Project Title: Walnut GrOve TH 1129 S <br /> Project Date: Thursday,May O8,2014 <br /> Company Name: HVAC Deslgns Inc <br /> Company Representative: Neil Fimbel <br /> Company Address: 7701 W Hanna Ave <br /> Company City: Tampa FL 33615 <br /> Company Phone: (813)885-2258 <br /> Company E-Mail Address: neil@hvacdesigns.com <br /> Company Website: http:l/www.hvacdesigns.coml <br /> Desi n Data <br /> Reference City: Zephyrhills,Florida <br /> Building Orientation: Front Door faces South <br /> Daily Temperature Range: Medium <br /> Latitude: 28 Degrees <br /> Elevation: 19 ft. <br /> Altitude Factor: 0.999 <br /> , <br /> Outdoor Outdoor Outdoor Indoor Indoor Grains <br /> Drv Bulb Wet Bulb Rel.Hum Rel.Hum Drv Bulb Difference <br /> Winter: 40 37.52 nla nla 72 nla <br /> Summer: 93 77 49% 55% 75 43 <br /> Check Fi ures <br /> Total Building Supply CFM: 600 CFM Per Square ft.: 0.531 <br /> Square ft.of Room Area: 1,129 Square ft.Per Ton: 1,029 <br /> Volume(ft)of Cond.Space: 9,034 <br /> Buildin Loads <br /> Total Heating Required Including Ventilation Air: 13,472 Btuh 13.472 MBH <br /> Total Sensible Gain: 9,878 Btuh 76 % <br /> Total Latent Gain: �� 3,173 Btuh 24 % <br /> Total Cooling Required Including Ventilation Air: 13,051 Btuh 1.10 Tons(Based On 75%Sensible Capacity) <br /> Notes <br /> Rhvac is an ACCA approved Manual J and Manual D computer program. <br /> Calculations are pertormed per ACCA Manual J 8th Edition,Version 2,and ACCA Manual D. <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's pertormance data at your design conditions. <br /> Thursday,May 08,2014,11:01 AM <br />
The URL can be used to link to this page
Your browser does not support the video tag.