��hvac-R�sidential&Light Commerclal HVAC Loads Elite Software Development,Inc. <br /> HVAC Designs � � Walnut Grove TH 1129 S <br /> Tam a FL 33615 Pa e 4 <br /> Manual D Ductsize Data-Duct S stem 1 -Return <br /> —Duct Name,etc. <br /> Type , Roughness Diameter Velocity SPL.Duct <br /> Upstream Temperature Width , Loss1100 SPL.Fit <br /> Shape Length Height Fit.Eq.Len SPL.Tot <br /> Sizin CFM Area SP.Avail SPL.Cumul <br /> —Duct Name:RMT•100,Feeds From:Foyer,Fitting:5-B,Effective Length:38.0 <br /> Trunk 0.003 12.4 665 0.002 <br /> Up:Fan 75 70 0.082 0.029 <br /> Rect 3.0 13 35.0 0.031 <br /> Schedule 600 11.5 -0.018 0.050 <br /> —Duct Name:RR•100,Returns From:Foyer,Fitting:2-D,Effective Length:22.2 <br /> Runout 0.003 12.4 665 0.001 <br /> Up:RMT-100 75 10 0.082 0.017 <br /> Rect 1.0 13 21.2 0.018 <br /> Schedule 600 3.8 0.000 0.018 <br /> Report Units:Pressure:in.wg,Duct lengths:feet,Duct sizes:inch,Airflow:CFM,Velocity:ft.lmin,Temperature:F <br /> Notes: Static pressure available values for returrr ducts are at the entrance of the duct. For supply,they are at the exit. The cumulative static <br /> pressure loss value for a return Uunk is with respect to the entry point of the return runout upstream with the highest static pressure available. Total <br /> and cumulative static pressure loss values for the supply main trunk include any device pressure losses entered,and the cumulative may also <br /> include the total static pressure loss of the return side. <br /> Summa <br /> Number of active trunks: 1 <br /> Number of active runouts: 1 <br /> Total runout outlet airflow: 600 � <br /> Main trunk airflow: 600 <br /> Largesttrunkdiameter: �. 12.4 RMT•100 <br /> Largest runout diameter: 12.4 RR-100 <br /> Smallest trunk diameter: 12.4 RMT-100 <br /> Smaliest runout diameter: 12.4 RR-100 <br /> Runout maximum cumulative static pressure loss: 0.018 RR•100 <br /> Return loss added to supply: 0.050 <br /> Total effective length of return(ft.): 60.2 RR-100 <br /> System duct surface area(Scenario 4): 15.3 Exposed in Space (Linked to duct load) <br /> Total system duct surtace area: 15.3 <br /> Notes <br /> Rhvac is an ACCA approved Manual J and Manual D computer program. <br /> Calculations are pertormed per ACCA Manual J 8th Edition,Version 2,and ACCA Manual D. <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at you�design conditions. <br /> Thursday,May 08,2014,11:01 AM <br />