+�thvac-R sidential&Light Commercial HVAC Loads Elite Software Development,Inc. <br /> HVAC Designs � � Walnut Grove TN 1129 S <br /> Tam a FL 33615 ' Pa e 6 <br /> Total Buildin Summa Loads <br /> Component Area Sen Lat Sen Total <br /> Descri tion . Quan Loss Gain Gain Gain <br /> OP LOW E MIN:Glazing-NFRC CODE MIN Operable 2 45.2 723 0 565 565 <br /> Pane Low E,ground reflectance=0.23,outdoor <br /> insect screen with 50%coverage,light color blinds <br /> at 45°with 100%coverage,u-value 0.5,SHGC 0.5 <br /> FD LOW E MIN:Glazing-NFRC CODE MIN Glass Door 2 20 320 0 278 278 <br /> Pane Low E,ground reflectance=0.23,light color <br /> blinds at 45°with 100%coverage,u•value 0.5, <br /> SHGC 0.5 <br /> 11 N:Door-Metal-Polystyrene Core 40 434 0 343 343 <br /> 128-Osw:Part•Frame,R-11 insulation in 2 x 4 stud 194.6 567 0 377 377 <br /> cavity;no board insulation,siding finish,wood <br /> studs <br /> 13A-4ocs:Wall-Block,board insulation only,R-4 board 296.2 1,356 0 775 775 <br /> insulation,open core,siding finish <br /> 13A-4ocs:Part•Block,board insulation only,R-4 board 92 395 0 263 263 <br /> insulation,open core,siding finish <br /> 16B-30•ad:RooflCelling-Under Attic with Insulation on 1129.3 1,157 0 1,915 1,915 <br /> Attic Floor(also use for Knee Walls and Partition <br /> Ceilings),vented attic,no radlant barrier,R-30 <br /> insulation,dark asphalt <br /> 22A-pm:Floor-Slab on grade,No edge insulation,no 86 3,247 0 0 0 <br /> insulation below floor,any floor cover,passive, <br /> heavy dry or light wet soil <br /> Subtotals for structure: 8,199 0 4,516 4,516 <br /> People: 3 690 900 1,590 <br /> Equipment: 640 2,040 2,680 <br /> Lighting: 0 0 0 <br /> Ductwork: 1,566 256 1,349 , 1,605 <br /> Infiltration:Winter CFM:105,Summer CFM:54 3,707 1,587 1,073 2,660 <br /> Ventilation:Winter CFM:0,Summer�CFM:0 0 0 0 0 <br /> Total Building Load Totals: 13,472 3,173 9,878 13,051 <br /> Check Fi ures <br /> Total Building Supply CFM: 600 CFM Per Square ft.: 0.531 <br /> Square ft.of Room Area: 1,129 Square ft.Per Ton: 1,029 <br /> Volume(ft)of Cond.Space: 9,034 <br /> Building Loads <br /> Total Heating Required including Ventilation Air: 13,472 Btuh 13.472 MBH <br /> Total Sensible Gain: 9,878 Btuh 76 % <br /> Total Latent Gain: 3,173 Btuh 24 % <br /> Total Cooling Required Including Ventilation Air: 13,051 Btuh 1.10 Tons(Based On 75%Sensible Capacity) <br /> Notes <br /> Rhvac is an ACCA approved Manual J and Manual D computer program. <br /> Calculations are performed per ACCA Manual J 8th Edition,Version 2,and ACCA Manual D. <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. <br /> Thursday,May 08,2014,11:01 AM <br />