Laserfiche WebLink
� ' � <br /> FOfdM 405-10 <br /> Florida Code Cornpliance Checklist � <br /> Florida Department of Business and Professional Regulations • <br /> Residential Whole Building Perfor►nance Method <br /> ADDRESS: 4408 Court StreSt PERMIT#: <br /> Zephyrhills,FL,33542 <br /> � <br /> MANDATORY REQUIREMENTS SUMMARY-See Indlvldual code sectiona for full details. <br /> COMPONENT SECTION SUMMARYOP REQUlREA9ENT(S) CHECK , <br /> Airleakage 402.4 To 6e caulked,gasketed, weathersfripped orofherwise sea/ed. <br /> Recessed lighting!C-rated as meeting ASTM E 283. Windows and <br /> doors=0.30 cfm/sq.ft Testing or visual inspecfion required. � <br /> Firep/aces:gasketed doors&outdoor combr�stion air. Must complete <br /> enve/ope leakage reporf or visually verify Table 402.4.2. <br /> Thermostat 8 403.9 At least one thermostat shall be provided for each separate heafing <br /> contr�ls and cooling system. Where forcec�air furnace is.primary system, - J <br /> programmable thermostat is required.Heat pumps wi�h supplemental �/ <br /> e/ectric heat must prevent supplemental heat when compressor can <br /> meet the/oad. • <br /> Ducts 403.2.2 All ducts, airhandlers, filterboxes andbuilding cavities which form the � <br /> primary sir containment passageways for air d.isfrrbution systems shall <br /> be considered ducts or p/enum chambers,shall be constructed and / <br /> seafed in accordance with Secfion 503.2.7.2 of this code. ✓ <br /> 403.3.3 Building framing cavities shall not be used as supply ducts. <br /> Water heaters 403.4 Heat frap required for vertica/pipe risers. Comply with efficiencies in <br /> Table 403.4.3.2.Provide switch or clearly marked circuit breaker �/ <br /> (e/ecfric)or shutoff(gas). Circulating sysfem pipes insu/afed to= <br /> �� R-2+accessib/e manus!OFF switch. � <br />� Mechanice! 403.5 Homes designed to operate at positive pressure or with mechanical <br /> ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. " <br /> . No make-up air from attics, crawlspaces,garages or outdoors adjacent ✓ ,' <br /> . to pools or spas. , <br /> SwimmingPools 403.9• 'Poo/pumps and poo!pump motors witf►a total horsepower{HP)of= 1 <br /> &3pas .. - HP'shall heve,the capability of operating at two ormore speeds. Spas <br /> ' � ' and.hested pools must have vapor-retardant covers or a liquid cover or, <br /> �',�� � � — , ofher means proven fo reduce heat loss except if 70%aof heat from �.�A <br /> { . , , site-recovered energy. Offitimerswitch required. Gas heaters minimum - � <br /> thermalefficiency=78%(82%after4/16/13). Heatpump pool heaters � <br /> � minimum COP=4.0. � <br /> Cooling/heating ' 403.6 Sizing ca/culation performed&attached.Minimum e�ciencies per � <br /> � Tables 503.2.3. Equipment efficisncy ver�cafion required. Special <br /> equlpment oci6asion cooling orheating capacityrequir�s separate system or . <br /> variable capacity system. Electric heat>?OkW must be divided into two . <br /> or mor�s stages. <br /> Ceilings/kneewalls 405.2.1 R-99 space permifting. . �. <br /> 5/8/2014 1:11 PM EnergyGaugeAUSA-FlaRes2010 Secdon 405.4.9 Comp!!an!Softwa�g Page 6 of 6 <br />