<br /> Rhvac-Residential&Lfght Commercial HVAC Loads Elite Software Development,Inc.
<br /> HVAC Designs � Walnut Grove TH 1456 S
<br /> Tam a FL 33675 ' Pa e 6
<br /> Total Buildin Summa Loads
<br /> Component Area Sen Lat Sen Total
<br /> Descri tion . Quan Loss Gain Gain Gain
<br /> OP LOW E MIN:Glazing-NFRC CODE MIN Operable 2 116.3 1,861 0 2,960 2,960
<br /> Pane Low E,ground reflectance=0.23,outdoor
<br /> insect screen with 50%coverage,light.color blinds
<br /> at 45°with 100%coverage,u•value 0.5,SHGC 0.5
<br /> FD LOW E MIN:Glazing-NFRC CODE MIN Glass Door 2 20 320 0 278 278
<br /> Pane Low E,ground reflectance=0.23,light color
<br /> blinds at 45°with 100%coverage,u•value 0.5,
<br /> SHGC 0.5
<br /> 11N:Door-Metal-Polystyrene Core 40 434 0 343 343
<br /> 12B•Osw:Part-Frame,R-11 insulation in 2 x 4 stud 154.6 450 0 300 300
<br /> cavity,no board insulation,siding finish,wood
<br /> studs
<br /> 13A-4ocs:Wall•Block,board insulatlon only,R-4 board 669 3,062 0 1,748 1,748
<br /> insulation,open core,siding finish
<br /> 13A-4ocs:Part•Block,board insulation only,R-4 board 124 532 0 355 355
<br /> insulation,open core,siding finish
<br /> 16B-30-ad:Roof/Ceiling-Under Attic with Insulation on 1455.9 1,491 0 2,469 2,469
<br /> Attic Floor(also use for Knee Walls and Partition
<br /> Ceilings),vented attic,no radiant barrier,R-30
<br /> insulation,dark asphalt
<br /> 22A-pm:Floor-Slab on grade,No edge insulation,no 142 5,362 0 0 0
<br /> insulation below floor,any floor cover,passive,
<br /> heavy dry or light wet soil
<br /> Subtotals for structure: 13,512 0 8,453 8,453
<br /> People: 4 920 1,200 2,120
<br /> Equipment: 640 2,040 2,680
<br /> Lighting: 0 0 0
<br /> Ductwork: 2,246 310 2,047 2,357
<br /> Infiltration:Winter CFM:136,Summer CFM:70 4,779 2,047 1,382 3,429
<br /> Ventilation:Winter CFM:0,Summer�CFM:0 0 0 0 0
<br /> AED Excursion: 0 0 652 652
<br /> Total Building Load Totals: 20,537 3,917 15,773 19,690
<br /> Check Fi ures
<br /> Total Building Supply CFM: 850 CFM Per Square R: 0.584
<br /> Square ft.of Room Area: 1,456 Square ft.Per Ton: 831
<br /> Volume(iP)of Cond.Space: 11,647
<br /> Buildin Loads
<br /> Total Heating Required Including Ventilation Air: 20,537 Btuh 20.537 MBH
<br /> Total Sensfble Gain:. 15,773 Btuh 80 %
<br /> T�tal Latent Gain: 3,917 Btuh 20 %
<br /> Total Cooling Required Including Ventilation Air: 19,690 Btuh 1.75 Tons(Based On 75%Sensible Capacity)
<br /> Notes
<br /> Rhvac is an ACCA approved Manual J and Manual D computer program.
<br /> Calculations are performed per ACCA Manual J 8th Edition,Version 2,and ACCA Manual D.
<br /> All computed results are estimates as building use and weather may vary.
<br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions.
<br /> Thursday,May O8,2014,1:03 PM