Laserfiche WebLink
; <br /> � <br /> �4��HA IN�'EL.�,IC�NT�►DC�RE�SAB�E NICl�UL.E� N�IX-1 t�0 S�RI�� <br /> � Featur�� <br /> �}~'����r;£,="'��� � Designed to meet a wide range of applicafians <br /> � '��::�;`M��,:...:'��'�' �. <br /> � � ��'� ���` For use with the FX-350 Series FireAlarm Control <br /> M..�...: ., • <br /> � :_.. - ,.��;� -- -— - - Panels <br /> .._ _ �'' ,u� <br /> e �,.�,�...�, • <br /> ^ Fast response time <br /> '%'Ri�yl,'1��,:��p':;�{: i�t. <br /> ',z t�' • Priority[nterrupt feature on monitor mociules <br /> MIX-1o1 P MIX-100P Monitor modules can be wired as a Class A(Style <br /> . e D}or Class B(Style B) <br /> �N� ,:: .,;4 <br /> � Each module can be addressed from 1 to 126 <br /> � ` "�� �'"'�� ° Eight position dip switch for address setting <br /> �y � �„�, <br /> ���.�» . �;=`=� � '_`�'#�� • Red light indicator <br /> ��-�: , <br /> �t: d.`F���.w ..._,.,.� <br /> �'��� a • Modules mount,in standard 4"junction box <br /> � <br /> M IX-'[QOS M IX-'t OOX <br /> �@SC 8'1�J$IOiI <br /> Mircom's Aipha Series lnte(ligent Addressab(e 9ntelligentAddressable Priority Bl�ini-iV�anitor <br /> Madules are designed to meet a wide range of �llodule(MIX-101�) <br /> applications. The monitor and control modules can The IntelligentAddressable Priority Mini Monitor Module <br /> be used#a supervise and activate sounders,strobes, provides an address for a group of UUULC �isted <br /> doar closers, pull .stations, waterflow switches, Normally Open (N.O.) initiating devices, such as heat <br /> conventional smoke detectors and more. An eight detectors, prajected beam smoke de#ectors; 4•wire <br /> pasition dip switch allows forthe address setting ofthe smake detectors, waterffow switches, manual pufl <br /> device and #he vviring class/style of the devices that stations, etc. wired in a Class A{Style D) or Class B <br />� are connected fia the module. All modules mount in tSfY�� �) initiating circuit. The MIX-101 R is equipped <br /> a standard 4"x 4"x 2 1/8"junction box. wi#h a priority interrupt to provide a fast response <br /> to emergency canditions. The MIX-101 P has an <br /> In#elligentAddressable Priarity Monitor Module activated red LED. � <br /> {M!X-900t�} . <br /> The lntelligent Addressa�le Priority Monitor Module �ntelligent Atldressable Retay Modute(iUitX-100R) <br /> (MIX-100P) provides an address for a graup of UL/ The IntelligentAddressable Relay Module cannects to <br />, ULC Listed narmally open {N.O.} initiating devices, the same[oop as the initiating devices and provides <br /> such as heat detectors, beam smoke detectors, 4- �� �solated sets of F'arm-C contacts ta control a <br /> wire smoke det�ctors, wate�'law switches, manual variety ofi narmally open ar normally closed cantact <br /> pull stations, etc. wired in a Class A (Style Q) or aPp�ications cuch as fan operation and door closures. <br /> � Class 8 (Style 8) ini#iating circuit. The M{X-1QOP The MIX-100R has an activated red LED which <br /> is equipped with a priority interrupt to provide a fast fotlows the state of the relay cantac#s. <br />; response to emergency conditions. The MIX-100P <br /> .:Tt�y <br /> has an activa#ecl red �ED. ��� :� <br /> U� ,°,.U�....� <br /> � ..�� <br /> S5434 55434 7150-1477�156 - <br /> GATA��G t�U119I�EF2 ���� <br /> NOT TO BE USEQ FOR INSTALLATION PURPpSES. <br /> Mircom reseives the righi to make cha�ges at any time withoui nafice in�rices,calours,materials,cornponents,equipmeni,speciftcations and models and also to discontinue models. <br />