My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
14-15318
Zephyrhills
>
Building Department
>
Permits
>
2014
>
14-15318
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/23/2015 11:02:55 AM
Creation date
6/23/2015 11:02:50 AM
Metadata
Fields
Template:
Building Department
Company Name
ROSS
Building Department - Doc Type
Permit
Permit #
14-15318
Building Department - Name
TOWNVIEW RETAIL LLC/CO STOLTZ
Address
7346 7348 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� SpectrAt�rt�clv�nce�pecificatio�� <br /> i - , <br /> General <br /> SpectrAlert Advance horns,strobes,and horn strobes shall mount ta a standard 4 x 4 x 1�/-inch back box,4-inch octagon back box,or <br /> double-gang back box.Two-wire products shal!also mount to a single-gang 2 x 4 x 1718-inch back box.A unlversai maunting piate shall <br /> t�e used for mounting ceiling and wa11 products.The notificatian appliance circuit wiring sha(I terminate at the universal mounting p(ate. <br /> Also,SpectrAlert Advance products,when used with the Sync•CircuiY"Module accessory,shall be po�vered from a non-coded notification <br /> appliance circuit output and shal!operate on a nomina!12 or 24 volts.When used wiih tt,s Syne•Gircuit Module,12-volt-rated notification <br /> appiiance eircuit outputs shal(aperate between 8 and 17.5 volts;24-vait-rated notification appliance circuit outputs shal�operate between 16 <br /> and 33 volts.Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DG or full-wave <br /> rectified unfiitered poever supp}y Strabes and horn sirobes shail have field-selectabie candeia settings includ3ng 15,1517b,30,75,95,110, <br /> 115, 135. 150, 177,and�85. <br /> Strobe <br /> The strobe shaii be a System Sensor SpectrAlert Advance Madel listed to UL 1971 and shall be approved for fire protective service. <br /> The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for <br /> vlsibie signaling app(iances,flashing at 1 Hz over the strobe's entire operating voEtage range.The strobe light sna(1 consist af a xenon f(ash <br /> tube and associated lens/reflector system. <br /> Horn Strobe Cambination <br /> The horn strobe shall be a System Sensor SpectrAlert Advance Model listed ta UL 1971 and UL 464 and shall be approved for <br /> fire protective service.The harn strobe shall be wlred as a primary-signalir�g notificatian appliance and compiy with the Americans with <br /> Disabilities Act requirements#or visible signaling appliances,flashing at 1 Hz over the strobe's entire operaiing voltage range.The strobe light <br /> shall consist of a xenan flash tube and associated lenslreflector system.The horn shall have three audibility options and an option to switch <br /> between a temporal three pattem and a non-tempora!(continuous)pattern.These options are set by a multiple pasitit�n switch.On#aur-wire <br /> products,the strobe sha((be powered independently of the sounder.The hom on horn strobe models shail operate on a coded or non-coded <br /> power supply, . <br /> Synchronization Module <br /> The module shall be a System Sensar Sync•Circuit madel MC1L listed to UL 464 and shall be approved for fire protective service.The module <br /> sha0 synchronize SpectrAlert sirobes at 1 Hx and homs at temparal three.Also,whi[e operating ti�e strobes,the module shall silence the horns <br /> on horn strobe models over a singie pair of wires.The module shall mount to a 411/16 x 411/16 x 21/8-inch back box.The module shall also <br /> control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize muitiple zones.Daisy chaining two or more <br /> synchronization moduies together wiEl syr�chro�ize all the zanes they car�trol.The madule shali not operate on a coded power supply. <br /> 3 <br /> Standard Operating Temperature 32°F io 120°F{d°C to 49°C} <br /> Humidity Range 10 to 93%nan-condensing <br /> Strobe F[ash Rate 1 flash per second <br /> Nominal Valtage Regulated 12 DC/FWR or regulated 24 DC/FWR' <br /> Operating Voltage h�angez 8 ta 17.5 V(i2 V nomir�a!}or 16 to 33 V{24 V�ominai} <br /> InputTerminat Wire Gauge 12 to 18 AWG <br /> Wall-Mount Dimensions(inciuding lens) 5.6"L x 4 7"'W x 2.5"D(142 mm L x 119 mm W x 64 mm D) <br /> Horn Dimensians 5.6`�x 4 7`"W x 1.3"'D{142 mm L x 119 mm W x 33 mm D) <br /> Wall-Mount Back Bax Skirt Dimensipns(BBS-2,BBSW-2) 5.9"L.x 5.0"W x 2.2"'D(151 mm L x 128 mm W x 56 mm D) <br /> Wafl-MoecntTrim Riu�g Dimensians(sold as a 5 pactc}{TR-HS,i'RYV- 5.7"�x 4.8"W x 4.35"'D{145 mm L x 122 r�m W x 9 mm D) <br /> HS} <br /> Nates: <br /> 1.Fuli Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. <br /> 2.P,S,PC,and SC products will operate at 12 V nominal only fpr 15 and 15/75 cd. <br /> .�V�500'o0t <br />
The URL can be used to link to this page
Your browser does not support the video tag.