Laserfiche WebLink
., � .� ,- <br /> r. . <br /> � - i • r <br /> . � - � - � - - <br /> SERVICE&INSTALLATION OF COMMERCIAL COOKING AND REFRIGERATION <br /> PROPOSED CONTRACT <br /> April 14, 2014 <br /> . Breakfast Station#6 LLC Quote#1411 <br /> 7331 Gall Blvd. Walk In Cooler <br /> Zephyrhills,FL <br /> Main Commercial Cooking&Refrigeration Service will furnish and install one complete Walk In <br /> Cooler as detailed below. <br /> SCOPE OF WORK REFRIGERATION <br /> Pull permit not to exceed $250.00 for installation of Walk In Cooler. <br /> Provide and del�iver 1 American Panel Walk-in Cooler for outdoor use,without floor, including <br /> refrigeration equipment,to job site measuring 5'10"x 7'9"x 7'2"high. <br /> Refrigeration system will include 1 Pre-assembled outside refrigeration system: <br /> 1 medium temp, 1 phase, 1/2 hp,208/230 volt condensing unit <br /> 1 evaporator <br /> Thermostatic expansion valve, sight glass, drier, solenoid valve,thermostat,winter controls, 35 degree <br /> operation, five year compressor warranty. <br /> 1 30"x 75"flush mount infitting door <br /> Cam-rise hinges,padlockable deadbolt handle, door closer, brushed hardware,programmable <br /> monitoring system 100 with digital thermometer, door frame heater, vapor proof light and switch with <br /> pilot light. <br /> Receive unload, inspect and erect walk-in panels for outdoor use at job site. <br /> Hang evaporator coils,provide and install drain line to outside of box. <br /> Set remote air cooled refrigeration equipment on provided level slab. <br /> 1 REFRIGERATION PIPING SYSTEM INSTALL <br /> Provide and install refrigeration piping, insulation,traps, fittings and hangers to provide a complete and <br /> operational system per all plans and specification's provided to MAIN Commercial at the time of this <br /> proposal. <br /> This proposal is based on a total amount of feet per line run for 1 system, (both liquid and suction lines will <br /> be defined as "1 run") and the total line runs for a112 systems shall not ezceed 25ft per run. "Runs" will be <br /> calculated by measuring from the condensing unit to each evaporator and additional "runs" going to any <br /> additional evaporators attached to a systems line run. <br /> Perform nitrogen leak test at 300 PSIG. <br /> Evacuate and Charge system. Start up and test for proper operation <br /> SCOPE OF WORK PROVIDED BY OTHERS: <br /> Any building roof, floor, and wall penetrations if reyuired. <br /> Any required pitch pockets/gooseneck need for these penetrations will not be provided by Main Commercial <br /> All required electrical work. <br /> Any fire sprinkler work, if required by code. <br /> Cont.... <br /> 16705 Sc/:eer Blvd.Hudsoi:,FL 34667 <br /> Toll Free: 877-868-8660 Pl:one: (727) 868-8586 Fnx: (727) 868-8650 <br />